background image

 

Bedienungsanleitung Steuerung S4_2006_09_25-neu.doc 

Page 4 / 83 

© wodtke GmbH Tübingen. All rights reserved. Subject to change without notice. 

Month of issue xx/2007 

Art. No. 950 281 

 

 

     

 

 

1  Important General Information  

Please read all attached instructions and information carefully before installing 
your  stove  and  putting  it  into  operation.  In  this  way  you  will  avoid  operating 
errors  and  malfunction.
  The  installer  and  the  user  must  inform  themselves 
sufficiently through the instruction manuals before putting the stove into operation
Please observe the relevant local technical codes and regulations (for ex. state 
building  regulations,  fireplace  regulations,  heating  and  ventilation  technical 
code, electrical/VDE guidelines etc).
 

 

In  Germany  the  appliance  may  only  be  put  into  operation  when  the  district 
master chimneysweep has issued an operating licence. 
Inform him in good time if 
you are planning to install or change a fireplace. 

 

The  pellet  stove’s  intended  use  is  described  below.  Any  other  use  will  be  deemed 
improper.  wodtke  will  assume  no  liability  for  any  damage  resulting  from  such  improper  use. 
Operating the pellet according to its intended use also means complying with the operating and 
assembly  instructions.  Any  inadmissible  manipulation  or  change  to  the  appliance  voids  all 
warranty and guarantee claims. 

 

All  work  on  this  stove,  including  installation,  assembly,  initial  operation,  servicing  and 
repairs,  should  only  be  carried  out  by  a  duly  qualified  company  (heating  or  air  heating 
installers).  Improper  work  performed  on  this  stove  voids  all  warranty  and  guarantee  claims. 
Electrical  devices  may  only  be  assembled  and  connected  to  the  mains  by  a  duly  qualified 
electrician
.  Electronic  components  such  as  circuit  boards,  air  flow  sensors  and  the  operating 
panel are sensitive to electrostatic charge. 

 

As  part  of  the  final  acceptance  procedure  the  installing  company  must  instruct  the  user  in  a 
detailed and competent manner on the stove’s operation, cleaning and servicing. The company 
must  in particular  inform  the  user on  the  use  of  suitable fuel,  the  need for  regular  cleaning  by 
the  user,  the  need  for  servicing  and  the  safety  instructions.  Any  disregard  of  the  attached 
instructions, in particular of the need for regular cleaning and servicing, voids all warranty and 
guarantee claims. 
Before  putting  the  stove  into  operation  make  absolutely  sure  that  all  accessories  have  been 
taken  out  of  the  firebox  and  ashpit  
and  the  fuel  hopper  is  free  of  residues  (for  ex.  rubbish, 
screws…). 

 

The appliance must regularly be cleaned by the user. 
For  the servicing  of the  appliance  we  recommend  that  the user make  a  service  contract  with 
his  dealer.  If  he  is  sufficiently  skilled  himself  and  has  been  instructed  in  due  detail  by  the 
installing company the user may also undertake the regular servicing himself. 

 

Pull the plug before performing any work on the stove! The mains plug and its 
socket must be easily accessible at all times. It is forbidden to operate the appliance 
if  the  power  cable  is  damaged.  A  damaged  power  cable  must  immediately  be 
replaced by a duly qualified craftsman to prevent hazards. 

 

Do  not  pull  the  mains  plug  while  the  stove  is  in  operation! 
First switch off the stove and wait until the fan after-run time 
is over (G OFF).
 
 
By  adhering  to  the  proper  use,  operation,  care  and  servicing  of  your  wodtke  products 
you  will  enhance  their  value  stability  and  service  life,  help  to  conserve  valuable 
resources and go easy on the environment as well as your purse.
 

 

Содержание CW 21 Airplus PO 04.7 E

Страница 1: ...anual before installing and putting your stove into operation This will help you to avoid damage that can occur from improper installation or operation and your stove will be a source of comfort and e...

Страница 2: ...n with igniters 16 5 6 Appliance types and programmes 17 5 7 Operating states functional messages 17 5 7 1 Overview of functional messages normal operation 17 5 8 Manual operation appliance switched o...

Страница 3: ...eaning the flueways on Waterplus appliance Smart 58 9 8 Cleaning the flueways on Waterplus appliance PE 61 9 9 Cleaning the flueways on Waterplus appliance Topline 64 9 10 Cleaning the flue gas fan an...

Страница 4: ...to the mains by a duly qualified electrician Electronic components such as circuit boards air flow sensors and the operating panel are sensitive to electrostatic charge As part of the final acceptanc...

Страница 5: ...ould always be planned with particular care since they not only produce heating water but through heat irradiation and convection also heat up the room of installation itself Please observe the follow...

Страница 6: ...d to water room of installation should account for at least 50 of total heated floor area Smart PE CW 21 Waterplus appliances 80 of thermal output delivered to water room of installation should accoun...

Страница 7: ...nal to accommodate the fan after run time 2 4 Heat delivery to water with Waterplus appliances The heat delivery to water during the operation of Waterplus appliances must be 1 6 kW at minimum since o...

Страница 8: ...rve the notes on in this in Chapter 11 Approved fuels Deviations from these specifications are unavoidable due to the DIN tolerance ranges allowed for pellets in terms of for ex ash content bulk densi...

Страница 9: ...mmediately after its initial operation and keep the invoice in a safe place To provide spare parts or respond to guarantee claims we always need the serial number of the appliance so that we can be su...

Страница 10: ...rs fuel at a rate corresponding to the selected thermal output level The air required for combustion is fed to the burner pot at a controlled rate The gas combustion process is completed in the firebo...

Страница 11: ...ve any additional information provided by us or ask your district master chimneysweep or the installing company Waterplus appliances not only deliver heat to the domestic water system but inevitably a...

Страница 12: ...e GmbH T bingen All rights reserved Subject to change without notice Month of issue xx 2007 Art No 950 281 All wodtke appliances are tested as design category 1 devices DIN 18891 DIN 18894 and it is t...

Страница 13: ...the menu level in any way except for switching it on or off with the I O key If 60 seconds elapse without a key being pressed the system will automatically return to the operating level 5 1 User level...

Страница 14: ...he door with the ceramic glass window becomes very hot during operation Make sure that nobody touches the window The panels may also become hot after prolonged operation Use the heat protection gloves...

Страница 15: ...to the fuel hopper When starting up for the first time the feed screw will still be empty The first pellets will fall into the burner pot when the appliance has been running for about 10 minutes and t...

Страница 16: ...not light the pellets by hand After a false start empty the burner pot completely and dispose of the pellets and ash Never return unburnt pellets from the burner pot to the fuel hopper and never try...

Страница 17: ...al operation Function Operating state Stand by dot manual operationappliance switched off via I O key H E OFF Automatic operation Appliance switched off via external controller T W OFF Automatic opera...

Страница 18: ...he appliance is off The Menu remains accessible when the appliance is switched off 5 8 1 Switching the appliance on via the I O key Pressing the I O key switches on the device After this the display b...

Страница 19: ...and its holes combustion air holes at least once a day and at the same time check that the burner pot is securely seated see Chapter 0 5 9 1 Switching the appliance on via an external controller The...

Страница 20: ...errors 5 10 1 Switching on and off via TW OFF When the Waterplus appliance is switched off by an internal controller after being in operation this is indicated by the messages G OFF and HE OFF flashin...

Страница 21: ...on pellet quality The preheating programme starts anew after every restart or power failure If the preheating programme doesn t work properly burner pot still full of unburnt pellets be sure to obser...

Страница 22: ...al controller calls for MAX again 5 12 3 Modulation heating programme via internal controller safety function display shows HM for modulation for minimal thermal output display shows dot between H and...

Страница 23: ...equired by the external controller In the case of external modulation the external controller will usually have two outputs of which one switches the device ON and OFF via the ON OFF input while the o...

Страница 24: ...s a result of an internal error or safety shutdown The purpose of having a fan after run phase after switching off the appliance is to ensure that flue gases are safely carried away and the entire fue...

Страница 25: ...leaned regularly see Chapter 0 Some tips of advice Ask you supplier to confirm the ash content of your pellets in writing This is a significant determinant of servicing frequency High quality pellets...

Страница 26: ...6 83 wodtke GmbH T bingen All rights reserved Subject to change without notice Month of issue xx 2007 Art No 950 281 Note Internal data processing rounding of operating cycles by the appliance can res...

Страница 27: ...002 or S4 003 etc Currently installed software version Indicates which software is on the circuit board It does not refer to the programme version which is what determines power capacity etc Z on or Z...

Страница 28: ...an after run G OFF counts as operating time R2 Relay output 2 See relay table Collective error message Shows that an error has occurred R4 Relay output 4 See relay table Functional message monitored s...

Страница 29: ...ON R2 collective error message R2 0 V error message R2 OFF R2 230 V no error message R2 ON R4 potential free On Off signal monitored break contact safety relay R4 closed stove off message R4 OFF R4 op...

Страница 30: ...the I O key once for every error Reset error acknowledgement for ex in the event of 2 errors press the I O key twice Class 1 error code Cause of error Desired values How to correct error TL HI Tempera...

Страница 31: ...mbient temperature is too low calorific output setting is too low Temperature remains below desired TR during operation Remedy in case 3 increase thermal output Reset via I O key TP Temperature at pel...

Страница 32: ...of new operating panel RE Er1 Bridge at auxiliary input is open Bridge wire auxiliary input is open or error in external component appliance Note The auxiliary input is for feedback from external acce...

Страница 33: ...rs are of secondary importance not safety relevant and there is no need for a manual reset once the cause of the error has been eliminated since the appliance will automatically resume regular operati...

Страница 34: ...e also 0 Only in Waterplus models TW OFF and G OFF blink alternately for duration of fan after run Measuring point internal boiler sensor heat exchanger FKY This is a control function rather than an e...

Страница 35: ...mperature increase beyond the desired range entered into the software will trigger an error shutdown 7 7 Temperature sensor at flue gas fan TR Located directly at the flue gas fan is a temperature sen...

Страница 36: ...ash wood pellets will cause a deposit to form on the viewing window which can vary in appearance from very bright to dark black the latter especially in the event of low load operation This is a natu...

Страница 37: ...tch the stove off and let it cool sufficiently Before cleaning remove the pot from the pot holder It is not fastened so you can just lift it out Clean burner pot air holes pot holder pot resting surfa...

Страница 38: ...agents nor glass or any other solvent containing cleaning agent Powder coated surfaces should be cleaned gently with a damp cloth not scoured Do not use scouring agents or other acid or caustic clean...

Страница 39: ...y become necessary before WA appears especially if the pellets have an ash content greater than 0 5 or the burner pot has not been cleaned regularly see Chapter 0 Some tips of advice Ask you supplier...

Страница 40: ...models These service routines require special skills and we therefore urgently advise you to have them done by a duly qualified company In addition to the special brushes supplied with the appliance...

Страница 41: ...e front panel by pulling it upwards taking care not to damage the glass Open the firedoor and fuel hopper lid 2 Release the middle screw and remove the slanted service cover by pulling it towards you...

Страница 42: ...Mind hot ash and hidden glowing embers 9 Vacuum burner pot Lift burner pot out and clean Clean combustion air holes with a suitable implement screwdriver if necessary 10 Vacuum pot holder and base pl...

Страница 43: ...hts reserved Subject to change without notice Month of issue xx 2007 Art No 950 281 11 Pull base plate out towards you and clean 12 Vacuum flueways thoroughly 13 Inspect flue gas fan for soiling Only...

Страница 44: ...ning the flueways on Airplus appliance Smart 1 Open the firedoor Lift upper panel and remove 2 Release wing nut on cast metal lid and remove fixing clamp Note Make sure you remount fixing clamp correc...

Страница 45: ...ing Mind hot ash and hidden glowing embers 9 Vacuum burner pot Lift burner pot out and clean Clean combustion air holes with a suitable implement screwdriver if necessary 10 Vacuum pot holder and base...

Страница 46: ...thout notice Month of issue xx 2007 Art No 950 281 11 Pull base plate out towards you and clean 12 Vacuum flueways thoroughly 13 Inspect flue gas fan for soiling 14 Only if flue gas fan requires clean...

Страница 47: ...t of its casing If necessary first remove base plate from in front of stove and cover floor if sensitive otherwise rollers might damage floor Open the firedoor 2 Release the 4 screws on the upper cove...

Страница 48: ...e chamotte and clean rear stove wall 8 Release both screws of inspection cover 9 Release the four screws of front inspection lid and remove inspection lid Make sure the sealing is correctly seated whe...

Страница 49: ...y combustion residues on the pot or pot holder Check that the burner pot is firmly seated in the pot holder and doesn t side wobble by more than 1 to 2 mm if it does you will need to replace the burne...

Страница 50: ...o 950 281 9 4 Cleaning the flueways on Airplus appliance Frank 1 Open the firedoor Lift upper panel and remove 2 Release wing nut on cast metal lid and remove fixing clamp Note Make sure you remount f...

Страница 51: ...embers 7 Vacuum burner pot Lift burner pot out and clean Clean combustion air holes with a suitable implement screwdriver if necessary 8 Vacuum pot holder and base plate thoroughly Important notes Whe...

Страница 52: ...ithout notice Month of issue xx 2007 Art No 950 281 9 Pull base plate out towards you and clean 10 Vacuum flueways thoroughly 11 Inspect flue gas fan for soiling 12 Only if flue gas fan requires clean...

Страница 53: ...al then pull it downward and remove 2 Remove the lid and the left and right front side panels 3 Remove upper heat reflector plate Release wing nuts on right and left flueways 4 Remove covers of left a...

Страница 54: ...the pot holder and doesn t side wobble by more than 1 to 2 mm if it does you will need to replace the burner pot wearing part The burner nose must point forward 8 Release both screws on inlet grille a...

Страница 55: ...en the firedoor and fuel hopper lid 2 Release the middle screw and remove the slanted service cover by pulling it towards you 3 Release wing nut on cast metal lid and remove fixing clamp Lift off cast...

Страница 56: ...h soot brush 8 Clean pipes of the water heat exchanger with a soot brush 9 Remove lower front panel 10 Release screws of front inspection lid and remove inspection lid Make sure the sealing is correct...

Страница 57: ...fully on the pot holder Remove any combustion residues on the pot or pot holder Check that the burner pot is firmly seated in the pot holder and doesn t side wobble by more than 1 to 2 mm if it does y...

Страница 58: ...emove 2 Release wing nut on cast metal lid and remove fixing clamp Lift off cast metal lid and remove Note Make sure you remount fixing clamp correctly when reassembling 3 Lift upper deflection plate...

Страница 59: ...at exchanger with a soot brush 8 Release both screws of inspection cover 9 Remove inspection cover 10 Release the four screws of front inspection lid and remove inspection lid Make sure the sealing is...

Страница 60: ...n residues on the pot or pot holder Check that the burner pot is firmly seated in the pot holder and doesn t side wobble by more than 1 to 2 mm if it does you will need to replace the burner pot weari...

Страница 61: ...from in front of stove and cover floor if sensitive otherwise rollers might damage floor Open the firedoor 2 Release the 4 screws on the upper cover and remove cover 3 Release wing nut on cast metal l...

Страница 62: ...rush 8 Clean pipes of the water heat exchanger with a soot brush 9 Release both screws of inspection cover 10 Release the four screws of front inspection lid and remove inspection lid Make sure the se...

Страница 63: ...y combustion residues on the pot or pot holder Check that the burner pot is firmly seated in the pot holder and doesn t side wobble by more than 1 to 2 mm if it does you will need to replace the burne...

Страница 64: ...e flueways on Waterplus appliance Topline 1 First take the spoiler and deflection plate out of the firebox 2 Then using a cleaning brush clean pipes and all 3 side walls of the water heat exchanger 3...

Страница 65: ...urner pot out and clean Clean combustion air holes with a suitable implement screwdriver if necessary An dieser Stelle ist im Deutschen ein Fehler Anm d XX 8 Vacuum firebox pot holder and base plate t...

Страница 66: ...and hidden glowing embers 12 Inspect flue gas fan for soiling Note In models of the Topline series the flue gas fan is screwed onto the stove in the rear left hand area You can check for soiling eithe...

Страница 67: ...clean the sleeve of the flue gas sensor inside the flue gas fan see picture removing any soot that may be clinging to it which would have an undesirable insulating effect Alternatively you can also di...

Страница 68: ...sensor and clean it together with the suction pipe if you find dust deposits or bunches of hair or the like see next chapter for dismounting instructions 2 2 Check air flow sensor LMS for soot or blac...

Страница 69: ...necessary for a diagnosis see above soiled pipe or sensor The air flow sensor is located in the combustion air suction pipe To dismount the sensor you need to remove various panels depending on the mo...

Страница 70: ...0 83 wodtke GmbH T bingen All rights reserved Subject to change without notice Month of issue xx 200x Art no 950 281 model series PE Release screws of side and rear panel and remove panels Release scr...

Страница 71: ...eassembly is done in the reverse order of assembly Important notes Remount the air flow sensor as shown in the picture The carrier plate must be located on the right as when looking in flow direction...

Страница 72: ...ition and at the correct depth see relevant chapter in the assembly instructions 9 15Finishing servicing work test run and service reset all models After completing all servicing work re establish all...

Страница 73: ...ugh uninsulated wall i e 10 cm clearance for air circulation required E 5 cm Minimum distance between flue gas connector and rear side of stove F 20 cm Minimum insulation of flue gas connector when fl...

Страница 74: ...lets and outlets must constantly be kept free and must not be blocked or covered in any way Danger of stove overheating Flammable objects must have a distance of at least 80 cm measure A from hot air...

Страница 75: ...damage to the pellet stove and burden the environment Operating the stove with an unapproved fuel voids all guarantee and warranty claims and can give rise to hazardous operating states Refrain from e...

Страница 76: ...50 h c 10 h c 100 h c 30 h c 100 h c 20 h c 110 h c 35 h at max telescope length c 110 h c 22 h at max telescope length c 100 h c 25 h c 100 h c 20 h CO content of flue gas 3 0 01 Vol Flue gas mass f...

Страница 77: ...wn up by Dipl Ing Dierk Astfalk Head of Technical Development Place date T bingen 01 05 2006 Legally binding signature This declaration certifies product conformity to the above Directives but it impl...

Страница 78: ...T bingen All rights reserved Subject to change without notice Month of issue xx 200x Art no 950 281 14 Dimensioned Drawings CW 21 Airplus PO 04 7 E CW 21 Waterplus PO 04 7 E WW Smart Airplus PO 04 6 E...

Страница 79: ...950 281 PE Airplus PE 04 6 E PE Waterplus PE 04 6 E WW Topline Airplus PO 04 8 E Topline Waterplus PO 04 8 E WW Legende xx Vorlauf heat flow R cklauf return flow Rauchrohrstutzen flue outlet Einbauli...

Страница 80: ...euerung S4_2006_09_25 neu doc Page 80 83 wodtke GmbH T bingen All rights reserved Subject to change without notice Month of issue xx 200x Art no 950 281 Frank Airplus PE 04 5 E flat door Frank Airplus...

Страница 81: ...l damage attributable to excessive chemical or thermal stress overvoltage faults attributable to operating errors or improper installation handling use cleaning servicing or operation Perforation of w...

Страница 82: ...ce or be unable rectify a fault When making complaints or ordering spare parts please state the date of installation as well as the serial number on the type plate of your appliance to ensure that you...

Страница 83: ...nungsanleitung Steuerung S4_2006_09_25 neu doc Page 83 83 wodtke GmbH T bingen All rights reserved Subject to change without notice Month of issue xx 200x Art no 950 281 Eingebettete Texte Anleitung M...

Отзывы: