5.2 Manual selection of thermal output
The desired thermal output of the appliance can be adjusted at any time using the +/- keys. The
selected value stays valid even after switching off the appliance and remains so until a new
value is entered manually. After completing the preheating programme the appliance enters the
heating programme, where it automatically delivers the selected thermal output so long as
this setting is not overridden by an internal or external controller (see modulation). The
selected thermal output is displayed in kW and can be adjusted in steps of 0.5 kW.
Tip: In buildings with rooms temperatures below +10 °C (for ex. holiday flats, new
buildings) we recommend setting thermal output to at least 4.0 kW.
5.3 Initial operation
Important information:
•
In Germany the appliance must be inspected by the district master chimneysweep before its
initial operation. The master chimneysweep is responsible for issuing an operating licence.
•
Always keep the firedoor closed, even when the appliance is cold.
•
Never light the appliance with flammable or readily ignitable liquids.
•
The door with the ceramic glass window becomes very hot during operation. Make sure that
nobody touches the window.
•
The panels may also become hot after prolonged operation. Use the heat protection gloves
delivered with the appliance.
•
Do not let children or adolescents come near the appliance unsupervised!
•
All steel and cast metal parts of the stove have been coated and baked with a highly heat-
resistant enamel at the factory. During the stove’s initial operation the enamel will undergo
an afterdrying process. This can give rise to odour and fumes! In this case please observe
the following:
o
Keep everyone including pets out of the room during this process, since the emitted
fumes may be harmful to health!
o
Air the room thoroughly to allow the fumes to escape.
o
During the afterdrying process the enamel will still be a little soft. Avoid touching
enamelled surfaces to make sure they don’t get spoilt.
o
Let the appliance run for some time at a high level to allow the enamel to harden
completely.
Complete the installation procedure as described in the assembly instructions before filling
pellets into the fuel hopper. Fill the hopper with at least 5 kg of wood pellets.
Make sure that no objects have been left in the firebox or burner pot.
* This dot also lights up to indicate stand-by mode
Feed screw indicator flashes or lights up while feed screw is running*
“H” indicates that heating programme is running
Display of selected thermal output = 4.0 kW
4.0
H .