Bedienungsanleitung Steuerung S4_2006_09_25-neu.doc
Page 17 / 83
© wodtke GmbH Tübingen. All rights reserved. Subject to change without notice.
Month of issue xx/2007
Art. No. 950 281
5.6 Appliance types and programmes
wodtke stoves have different software programmes installed depending on the model. The
programme number appears for a few seconds on the display after switching on the appliance
via the I/O key. The present operating manual only applies with the initially installed software
(you can check this from menu level 1 – see Chapter 0).
P1 (Programme 1): Airplus appliance; thermal output 2 - 6 kW
P2 (Programme 2): Airplus appliance; thermal output 2 - 8 kW
P3 (Programme 3): Waterplus appliance; thermal output 2 - 10 kW
Each programme exists in different versions (updates). The
programme version is indicated by the number in the second line.
5.7 Operating states & functional messages
A distinction must be made between different operating states and functional messages. The
display tells you at any time under which programme your appliance is operating.
•
Manual operation / Appliance switched off via I/O key: message “stand-by dot “
•
Automatic operation / Appliance switched off via external controller: (message
“HE OFF”)
•
A
5.7.1 Overview of functional messages (normal operation)
Function
Operating state
.
“Stand-by dot”,
manual operationappliance switched off
via I/O key
H E OFF
Automatic operation
Appliance switched off via external controller
T W OFF
Automatic operation (only with Waterplus appliances) appliance switched off via internal
controller
A -15
Ignition programme
countdown in minutes
AI 15
Ignition starta in x minutes (swaps with G off)
countdown in minutes
H 4.5
Heating programme
with manual output selection display of thermal output in kW
H M 2.0
Modulation heating programme via external controller (2-stage)
display of thermal output in kW
H.M 2.0
Heating modulated by internal controller (safety function = 1 dot lights up between H and M)
display of thermal output in kW
H E 4.5
Modulation heating programme via external controller (continuous controller)
display of thermal output in kW
R 120
Cleaning programme
countdown in seconds
G OFF
Fan after-run
(15 minutes duration)
5.8 Manual operation / appliance switched off via I/O key
= display shows “stand-by dot” in top right field
= ready to be switched on manually
= not ready for external controller / automatic operation!
= thermal output adjustable, functional values available via “Menu”
After proper installation and connection to the mains the display should show
“G Off” for fan after-run or (if fan after-run has already ended) the “stand-by
dot”. When it appears alone the “stand-by dot” at the top right indicates that
P3
400
Programme
Programme
version
.