1.
Loosen the material supply hoses includ
-
ing the male nipple and ball valve on both
sides of the manifold
➀
,
(Fig. 7.6).
2.
Remove the side plugs on the manifold
➁
,
(Fig. 7.6).
➀
➁
➀
➁
Fig. 7.6
3.
Wet the screw thread of the screw con-
nections with a thread-locking compound
and screw the material hoses into the side
openings on the manifold
➂
,
(Fig. 7.7).
Tighten up the connections.
4.
Insert the plugs into the original material
inlets
➃
,
(Fig. 7.7).
➂
➃
➂
➃
Fig. 7.7
7.2 Conversion to an automatic spray gun
To use the spray gun as an automatic gun,
the gun handle must be exchanged with an
adapter,
(Fig. 7.8).
The order number can be found in chapter
“9.2 Optional upgrades”, page 9-1.
Fig. 7.8
1.
Remove the manifold
➀
from the gun
body,
(Fig. 7.9).
Follow the work steps 1 to 5 as described
in
chapter “5.1.3 Venting”, page 5-2.
➀
➁
➁
➂
Fig. 7.9
2.
Loosen the screws
➁
on the gun handle
➂
and pull this from the housing,
(Fig.
7.9).
Make sure that the two cylindrical pins
➃
as well as the 3 O-rings
➄
remain in the
housing,
(Fig. 7.10).
➄
➃
Fig. 7.10
3.
Fasten the adapter for automatic oper-
ation
➅
to the mounting surface for the
handle on the housing. For this use both
fastening screws
➆
of the handle,
(Fig.
7.11).
➅
➆
➆
Fig. 7.11