Operation
5.7
Decommissioning
If you want to decommission the system for a longer period of time,
proceed as follows:
1.
Flush the equipment as described (see Chapter 5.3 Flushing on
page 35).
2.
Do not drain the pump fully.
Turn down the operating pressure fully (0 bar) as soon as clean
solvent is emitted from the spray gun or the drain hose on the
high pressure filter.
3.
Close the compressed air shut-off valve.
4.
Hold the spray gun laterally against the inner wall of the collect-
ing vessel and open it again.
5.
Hold the drain hose into the collecting vessel and open the
drain valve briefly to release the pressure.
The cleaning agent which is still in the equipment remains in the
equipment until recommissioning to prevent the equipment parts
from sticking.
For longer idle times the equipment has to be filled with a release
oil as the cleaning agent will evaporate over time.
5.8
Disposal
³
Rests of spraying material, cleaning agent, oils, greases and
other chemical substances must be collected in accordance
with statutory provisions concerning recycling and waste dis-
posal. The official local waste water laws are valid.
At the end of use, you must shut down and dismantle the equip-
ment and dispose of it in accordance with legal regulations.
³
Clean the equipment thoroughly of all material residues.
³
Dismantle the equipment and separate all materials – dispose
of metal together with scrap metal; plastic parts can be dis-
posed of as domestic waste.