Translation of the original operation manual
37
Airless 270_BAoDB_en_1405 • 0550022 • jw
Operation
6.
Remove the nozzle from the spray gun.
Observe and follow the notes in the user manuals for the spray
gun.
7.
Remove the filter element from the high pressure filter (see
Chapter 6.4.4 Cleaning the filter element on page 44).
8.
Remove the suction pipe from the material container.
Remove any paint residue on the suction pipe and the strainer.
9.
Place the suction pipe and strainer into the container with the
cleaning agent.
10.
Open the compressed air shut-off valve.
11.
Set the air regulator to a low operating pressure so that the
pump runs slowly.
12.
Open the drain valve on the high pressure filter until pure clean-
ing agent is emitted.
13.
Close the drain valve.
14.
Hold the spray gun laterally against the inner wall of the collect-
ing vessel.
15.
Open the spray gun until pure cleaning agent is emitted.
16.
Close and secure the spray gun.
5.4
Material change
1.
Clean the equipment as described in Chapter 5.3 Flushing on
page 35.
2.
Drain the equipment by removing the suction pipe from the
cleaning agent and opening the spray gun until air is emitted.
3.
Close and secure the spray gun.
4.
Fully reduce the air inlet pressure (0 bar).
5.
Release the pressure in the equipment (see Chapter 5.5 Re-
lieve pressure on page 38).
6.
Check the filter element in the high pressure filter (see Chapter
6.4.4 Cleaning the filter element on page 44).
7.
After finishing the task you can start spraying a new material
(see Chapter 5.2 Spraying on page 33).