Gearless Lift Machine
WSG-S2.4
Operating Instructions
Code
GM.8.003290.EN
Date
13.06.2016
Version
0.10
Page
23
Subject to changes without notice ! Subject to changes without notice !
EN
7.
Type code
Example:
W
S
G- S2 .
4
-
0
E
1 9
/
3 T I
-
D F
W
S
G- S2 . 4
-
X1
X2
X3 X4
/
X5 X6 X7
-
X8 X9
Customer specific
identifier
S = Synchronous motor
G = gearless
U = gearless; UL-CSA approved
Frame size
Overall length:
X1: Customer specific identifier
X2: Motor voltage:
E: serie „ECO“, suitable for inverter supply using a link voltage
of 500 …. 620 V
X3 X4: Rated speed:
e.g. 07: 75 min-1 (with D
T
= 320 mm v = 0.63 m/s; suspension 2:1)
11: 119 min-1 (with D
T
= 320 mm v = 1.0 m/s; suspension 2:1)
19: 191 min-1 (with D
T
= 320 mm v = 1.6 m/s; suspension 2:1)
X5 X6 X7: Traction sheave design
(Traction sheave diameter; width, groove design, groove geometry)
X8 X9: Variant code (brake, measuring system, modifications)
DZ: dual-curcuit brake; measuring system Sendix 8.5873-2048 Inkr. - BISS-Interface
DE: dual-curcuit brake; measuring system ECN 413-2048 incr. - SSI-interface
HE: dual-curcuit brake with manual release; measuring system ECN 413-2048 incr. - SSI interface
DF: dual-curcuit brake; measuring system ECN 413-2048 incr. - ENDAT-interface
DG: dual-curcuit brake; measuring system ERN 487-2048 incr.