L
F
= 300
b
a
Gearless Lift Machine
WSG-S2.4
Operating Instructions
Code
GM.8.003290.EN
Date
13.06.2016
Version
0.10
Page
28
Subject to changes without notice ! Subject to changes without notice !
EN
Lever block
Threaded
rod
10.3. Brake manual release
Alternatively, another simple version of the manual re-
leasing device is available for lifts with a machine room.
As an option the brake is available with a manual release.
Brake with or without manual release as specified with the
order. No possibility for retrofit !
The necessary manual release lever including the Bowden
cable for releasing can be delivered, if required.
The standard length of the Bowden cable is 3 m. Other
lengths on request.
Installation:
Install the manual brake releasing device with the brake dis-
connected from the power supply.
• Lock the car and the counterweight. Ensure that the re-
quired safety measures are observed for the lift system.
• Install the lever block.
• Insert the Bowden cable into the brake lever (a and b)
and the lever block . Adjusting of the Bowden cable on
the lever block. Set
L
F
= 300 mm
on the lever block with
the assistance of threaded rod.
Do not actuate the lever block !
• Perform a functional test (at least three times).
The Bowden cable has to be installed in wide
arcs only (bending radius > 0.5 m, if possible).
Put no loops !
Release
Lever extension