Mechanical installation
INTORQ | BA 14.0196 | 04/2016
34
4.6
Cover ring assembly
Fig. 20
Cover ring assembly
1. Disconnect electrical connection.
2. Pull cables through the cover rings (13).
3. Push cover rings (13) over the complete stators (1).
4. Press the lips of the first cover ring (13) into the groove of the complete stator (1) and flange (6) / end
shield.
5. Press the lips of the second cover ring into the groove of the first and second complete stator (1).
6. Re-establish the electrical connection.
NOTICE
Brakes without flange require a groove at the end shield for the lip of the cover seal.
1
Stator, complete
6
Flange
13 Cover ring
NOTICE
Cover ring with condensation drain hole:
Attach the cover ring so that condensation can drain through the hole.