DIP-Switch
Änderungen vorbehalten!
Subject to change without notice!
Blatt/
sheet
PM.7.002883.EN.42
Datum/
date
23.01.2013
Stand/
version
J-31.08.2017
Geprüft/
approved
WAT/MZE
Overspeed governor EOS
Operating instructions
4.9
Description of the LEDs (optional)
OFF
CHARGE
BATT ERR*
Description
OFF
1.
The line power has failed, the EOS is powered
from the battery.
2.
The electronic performs a battery test
3.
The electronic interface has just been started
and carries out a startup test
ON
OFF
The accumulator is charging.
ON
ON
The accumulator is discharged deeply. It is charged until
it´s sure, if it is broken or not (max 30min).
flashing
OFF
The accumulator is fully charged.
OFF
ON
1.
There is no accumulator attached.
2.
The accumulator is broken.
POWER
The LED is on if the electronic is active.
4.10 DIP-Switches (optional)
OFF
ON
S1/1
Runtime after line fail: 30 Min.
Runtime after line fail: infinite
S1/2
Battery Error output: NO (normally open) Battery Error output: NC (normally closed)
*
This applies only if the DIP switch S1/2 is turned off. If S1/2 is switched ON, the Batt-Err-LED behaves
exactly the opposite.
It is recommended to switch S1/1 to OFF
ENM1
Description
OFF
The UCM function of the EOS is activated
ON
The UCM function of the EOS is deactivated
ENM2
OFF
ON
OFF
Invalid state, must not occur in normal operation
ON
Invalid state, must not occur in normal operation
ON
OFF
LEDs of the EOS Interface Electronic with UPS
The Battery Error LED is on if the battery is ok and
DIP Switch S1/2 is set to on.
The Battery Error LED is off if the battery is OK and
DIP Switch S1/2 is set to off.