Änderungen vorbehalten!
Subject to change without notice!
Blatt/
sheet
PM.7.002883.EN.32
Datum/
date
23.01.2013
Stand/
version
C-13.10.2014
Geprüft/
approved
WAT/MZE
Overspeed governor EOS
Operating instructions
The inductive sensoric’s signal is used as additional
input for the lift-controller.
ETS only for EOS D200mm
The signal may be
used only as reference
to
another available source.
The encoder is delivered with cable
but without plug.
Specification of the sensor
Wiring assignment:
Sensors
Sensor ring
illustration without front stand
4.3.10 Impulse signal (optional reference input signal for emergency-terminal-slowdown-device
(ETS))
Acculex
SIPC8 - C2 PNP NO
type
6 .. 30 VDC
< 1.8 V
200 mA
Voltage supply
range
Voltage drop
(sensor on)
max. output
current