Änderungen vorbehalten!
Subject to change without notice!
Blatt/
sheet
PM.7.002883.EN.38
Datum/
date
23.01.2013
Stand/
version
23.01.2013
Geprüft/
approved
WAT/MZE
Overspeed governor EOS
Operating instructions
N
L
PE
PE
S1a
S1b
PE
S2a
S2b
PE
K1
K2
+24
GND
ENM1
Trip
Reset
ENM2
Bat1
Bat2
EOS supply
Safety
Circuit
Movement
Limited
Encoder
X7
X5
X3
X4
+24V
GND
ENM1
Trip
Reset
ENM2
EOS UCM
Safety Circuit
Lift Controller
Landing (Car)
Door Contact
Car (Landing)
Door Contact
Km
N
L
PE
Optional
Line
Supply
230VAC
Safety circuit without parallel loop to the door contacts, electronic interface with box
This type occurs in simple installations without advanced door opening and without releveling.
The supply voltage of the main contactors and the brake (Km) is used for the control of the UCM
function (inputs K1, K2).
4.7.1
Wiring diagram of the electronics (with box)
EOS Electronic Interface
with UPS
Safety Circuit Equivalent
Landing (Car)
Door Contact
Car (Landing)
Door Contact
Km
EOS X7
Emergency
Rescue
Switch S3
(inside Box)
S2a
S1b
S1a
S2b