14 Functional test
(when the door is open)
• Connect the power supply: connect the battery 9V block with the battery clip in the input unit or switch on the external power
supply.
• Enter the factory code:
Lock Primor 100:
1 – 2 – 3 – 4 – 5 – 6
Lock Primor 1000/2000/3000/3010/3011:
Level 5: 1 – 2 – 3 – 4 – 5 – 6
Level 15: 1 – 2 – 3 – 4 – 5 – 6 – 7
Re-enter the factory code when the power was switched off.
Primor 100/2000:
• Turn the input unit (Primor RO) or the opening lever (Primor RE) within 3 seconds into opening position. The lock is opened.
• Turn the handle into opening position.
• Closing shall be performed in reverse order.
Primor 1000:
• Within 3 seconds turn the boltwork’s handle into the opening position. The bolt swings in (has to happen easily). The lock is
opened.
• Turn the boltwork’s handle into the locking position. The swing bolt automatically folds out and locks. The lock is closed.
Primor 3000/3010/3011:
• The lock’s bolt opens automatically (has to happen easily). The lock is opened.
Turn the handle within 3 seconds into opening position.
• Turn the handle into locking position. The lock’s bolt closes automatically and blocks. The lock is closed.
15 Testing the system (programme 5)
Press every number once. A functional key will be confirmed by a double signal. A key that was not identi-
fied is confirmed by a long signal and the functional test is aborted. The system has to be checked.
1. Press and hold the key “5“ until the red LEDs flash permanently.
5
2. Press every key in its order of appearance.
123
.......
90