• EXPOSURE
Enable and configure exposure settings. The user has options for:
•
BRIGHTNESS; which may be adjusted from 1 to 100.
•
IRIS; which may be set to Auto or Manual. In the Manual setting, the user may select the F-Stop number preferred.
•
SHUTTER; which may be set to:
•
Manual; which may be adjusted from 512 to 1/120000.
•
A-FLK to help compensate for flicker. Flicker often happens when the frequency of the local light clashes with
the camera module.
•
ESC (Electronic Still Camera) to automatically control the shutter speed.
•
AGC; which may be set to OFF, LOW, MEDIUM, HIGH, Manual. In the Manual setting, the user may select the
Automatic Gain Control level from 5 to 41dB.
•
SSNR3; which may be adjusted from 1 to 32 on the WPS-500-PTZ-A or set to LOW, MEDIUM, or HIGH on the
WPS-750-PTZ-A.
•
SENS-UP; which may be set to OFF or Auto. In the Auto setting, the user may select the limit from 2x to 512x.
• SPECIAL
Allows the user to set extra camera features, the user has options for:
•
DAY/NIGHT; which may be set to Auto, EXT, COLOR, or B/W. In the Auto setting, the user may select the dwell time
from 5 to 60 seconds and the duration to SLOW or FAST. In the COLOR setting, the user may set the burst level. In
the B/W setting, the user may select the burst mode.
•
DIS (Digital Image Stabilization); which may be set to OFF or ON.
•
Image Adj; where the user may set up H-REV (Horizontal Reverse) and V-REV (Vertical Reverse) as well as
Sharpness from level 1 to 31.
•
MONITOR; which may be set to CRT, LCD, or USER. In the CRT setting, the user may adjust the pedestal (PED) level
to adjust the black level of the CRT from 0 to 70. The color level may be adjusted from level 1 to 100. In the LCD
and USER setting, the user may adjust the gamma level from 0.2 to 1.0, the PED level and the color level.
•
DISPLAY; where the user may set camera title, language, OSD color and motion alarm.
• RESET
Reset the Camera Options menu to default configuration. Highlight the option and press “Iris +” (“OPEN”) to complete
the reset.
• EXIT
Highlight and press “Iris +” (“OPEN”) to return to the main setup menu.
Содержание 750-PTZ-A-WH