30
WPS-500/750-PTZ-A Installation Manual
6.
Troubleshooting
If you have trouble operating the camera, first refer to the following guidelines. If the problem persists, contact our
Technical Support line at (866) 838-5052.
Nothing appears on the display
• Check if the power for the camera and the monitor is ON.
•
Check if the VIDEO cable is connected to the camera BNC video output jack.
•
Check if the VIDEO cable is connected to the monitor VIDEO input jack.
Image appears dim on the display
• Check the monitor contrast setting.
• Check the monitor brightness setting.
• Check the lens. If necessary, clean with a soft, clean eyeglasses cloth.
Image appears blurry on the display
• Check the lens. If necessary, clean with a soft, clean eyeglasses cloth.
The camera is not working properly and the camera housing is hot, or power cycles intermittently
• Check if camera is connected to the correct power source.
•
Check voltage at camera for proper voltage level.
• Connect camera locally with a different power supply to test.
The camera does not boot up when power is applied
• Check the power outlet or power supply to see if it is not connected correctly or not working.
•
Check the power supply to be sure it is outputting 24V AC when plugged in.
After powering up, the camera doesn’t respond to PTZ commands
•
Make sure the PTZ ID, protocol, and baud rate are set correctly in both the camera and PTZ controller.
•
Check the polarity of the RS485 wires. If “+” and “-” wires are reversed, RS485 won’t work.
WPS-500-PTZ-A has a yellow line in video
•
Open camera dome and check that the Yellow tab is removed from the Lens.
WPS-500-PTZ-A camera shakes after a restart
• It is normal for the camera to shake after a reset because the TILT function resets as well.