11
© 2014 Wirepath Surveillance
WPS-500/750-PTZ-A Installation Manual
3.5.
In-Ceiling Mount (WPS-500-PTZ-A ONLY)
3.5.1. Mounting and Use Guidelines
• Install only in areas where water cannot enter the opening made for the bracket.
• Ceiling must be able to hold the weight of the mounted camera assembly.
•
Tie wire where required by building codes.
IMPORTANT: DO NOT REMOVE THE PROTECTIVE PLASTIC FILM FROM THE CAMERA DOME UNTIL INSTALLATION IS COMPLETE!
3.5.2.
Assembly Instructions
1. Remove the top cover and sun shade from the camera. It will not be used with this mounting accessory. (Figure 1)
2.
Slide the camera into the mount and rotate the camera to lock the slots together. The screw holes will align when the
camera is correctly positioned. (Figure 2)
3. Secure the camera using the 3 screws included with the in-ceiling mount. (Figure 2)
3.5.3. Mounting Instructions
1.
Center the mounting template on the camera location and mark the outline for the opening.
2.
Use a saw to cut the opening. Remember, cutting a small hole and enlarging it will take less work than cutting the hole
too large.
3. Connect the wiring harness to the camera and the wiring. Use the wiring chart in section “3.2. Wiring Requirements” on
page 8 for reference.
4. Set the dip switches and record the settings. Use the chart on the camera or see section “3.9. Dip Switch
Configuration” on page 15.
5.
Insert the connected camera/mount assembly into the opening and evenly tighten the 3 Phillips screw dogs to secure
the mount.
6.
Attach the trim ring to the camera. If the ring will not sit flush with the ceiling, check to make sure the screw dogs are
evenly tightened.
7.
The camera may now be powered on and tested.
8.
See section “4. OSD Setup Menu” on page 17 for advanced setup or the troubleshooting section on page 30 for
diagnosing issues.
Figure 1.