ACW-DINDxxx_UG_EN_V1.8
Byte 0
Byte 1
0x01
0x03
The ACW will return a confirmation in the following format:
Description and Value
Byte 0
Answer to command frames: 0x07
Byte 1
Configuration command by default: 0x03
Byte 2
Indicates whether the reconfiguration went well:
⚫
Returns 0x00 to indicate that the configuration went smoothly.
⚫
Returns a value other than 0x00 to indicate that the configuration failed.
Obtain the complete configuration (Command 0x04)
To obtain the complete configuration of the ACW, it will be necessary to send him the following
command:
Byte 0
Byte 1
0x01
0x04
The ACW will return several frames with all its parameters:
Description and Value
Byte 0
Answer to command frames: 0x07
Byte 1
Configuration command by default: 0x04
Byte 2 to n
The parameters are encapsulated in the configuration frames.
Obtain the version of the used protocol (Command 0x07)
To obtain the version of the Downlink ATIM protocol implemented in the ACW, the following command
must be sent:
Byte 0
Byte 1
0x01
0x07
The ACW will return the version in the following format:
Description and Value
Byte 0
Answer to command frames: 0x07
Byte 1
Command version of the protocol: 0x07
Byte 2
Protocol version LSB
Byte 3
Protocol version MSB
Apply a value to the counters (from version V1.2.0) (Command 0x0A)
To write the value of one or more counters, it will be necessary to send him the following command:
Byte 0
Byte 1
Byte 2
Byte 3
Byte 4-7
0xC1
Frame size - 0x06
0x0A
Meter Index
Meter(s) value
The value of one or more counters is defined in bytes 5 to 8. The value is on 32 bits with the LSB first
(byte 5).