32
ACW-DINDxxx_UG_EN_V1.8
Shock alarm configuration (code 41)
Byte 1 possible values are :
•
0x00 => shock alarm radio frame disabled
•
0x01 => shock alarm radio frame enabled
b.
Commands
Restart (Command 0x01)
To restart the ACW-DINDIO8 / 16 remotely, you will need to send the following command:
Byte 0
Byte 1
0x01
0x01
The ACW will restart and not send confirmation.
About (Command 0x02)
To obtain the information about the ACW-DINDIO8 / 16 it will be necessary to send him the following
command:
Byte 0
Byte 1
0x01
0x02
The ACW will return the information in the following format:
Description and Value
Byte 0
Answer to command frames: 0x07
Byte 1
About command: 0x02
Byte 2
Type de l’ACW :
⚫
DIN D160 - 9
⚫
DIN D80 - 11
⚫
DIN D88 - 15
⚫
DIN D44 - 14
Byte 3
ACW version (LSB)
Byte 4
ACW version (MSB)
Byte 5
Radio type:
1.
Sigfox only uplink - 0x03
2.
Sigfox uplink/downlink - 0x04
3.
LoRaWan - 0x05
Byte 6
Radio version (LSB)
Byte 7
Radio version (MSB)
Byte 8 to n
Serial number (devEUI|sfx) (MSB first).
Reconfiguration with default settings (Command 0x03)
To reconfigure the parameters to the default values, it will be necessary to send him the following
command:
Size and Code (Byte 0)
Value (byte 1)
0x00|0x29 = 0x29
0xYY