Press
Slope On/Off
to activate the ALC power slope
function.
Press
Edit Pivot
to open the pivot point frequency
parameter for editing. Edit the current frequency us-
ing the cursor control key or rotary data knob or en-
ter a new value using the keypad and appropriate
termination key. When you have finished setting
the open parameter, close it by pressing
Edit Pivot
again or by making another menu selection.
Press
Edit Slope
to open the slope parameter for ed-
iting. Edit the current slope value using the cursor
control key or rotary data knob or enter a new value
using the key pad and the
STEPS
termination key.
When you have finished setting the open parameter,
close it by pressing
Edit Slope
again or by making
another menu selection.
While monitoring the power level at the device-un-
der-test (DUT), adjust the power slope and pivot
point to level the power at the DUT.
LOCAL (FRONT
LEVELING
PANEL) OPERATION
OPERATIONS
SLOPE
When Power Slope is selected ON,
this status message is displayed on
all menu displays to remind the op-
erator that a power slope correction
has been applied to the ALC.
3-62