![Wiltron 681 A Series Скачать руководство пользователя страница 87](http://html1.mh-extra.com/html/wiltron/681-a-series/681-a-series_operation-manual_984232087.webp)
Configuring
the Rear
Panel
Configuring the rear panel of the sweep generator
consists of selecting the polarity of the retrace blank-
ing, bandswitch blanking, retrace penlift, and video
marker outputs.
To go to the Configure Rear Panel menu from the
System Configuration menu, press
Rear Panel
.
The Configure Rear Panel Menu (shown below) is
displayed.
Press
Bl/–
to select a +5V or –5V level for
the retrace and bandswitch blanking output at the
rear panel
RETRACE BLANK OUT
connector. The
display will reflect your selection.
Press
Penlift
to select normally-open (
N/O
) or nor-
mally-closed (
N/C
) contacts on the internal penlift
relay. The penlift relay output, available at the rear
panel
PEN LIFT OUT
connector, is used to lift a plot-
ter pen during retrace.The display will reflect your
selection.
Press
/–
to select a +5V or –5V level for
the video marker output at the rear panel
MARKER
OUT
connector when video markers are selected
ON. The display will reflect your selection.
When done, press
Previous Menu
to return to the
System Configuration menu.
LOCAL (FRONT
SYSTEM
PANEL) OPERATION
CONFIGURATION
681XXA OM
3-65