en
Faults, causes and remedies
70
WILO SE 2020-10
Classification
No.
Fault
Cause
Remedy
Error type
Electronics er-
rors
E070
Internal com-
munication er-
ror (SPI)
Internal elec-
tronics error
Contact cus-
tomer service
A
A
E071
EEPROM error
Internal elec-
tronics error
Contact cus-
tomer service
A
A
E072
Power section/
frequency con-
verter
Internal elec-
tronics error
Contact cus-
tomer service
A
A
E073
Impermissible
electronic
module num-
ber
Internal elec-
tronics error
Contact cus-
tomer service
A
A
E075
Charging relay
defective
Internal elec-
tronics error
Contact cus-
tomer service
A
A
E076
Internal trans-
former defect-
ive
Internal elec-
tronics error
Contact cus-
tomer service
A
A
E077
24 V operating
voltage for dif-
ferential pres-
sure sensor de-
fective
Differential
pressure sensor
defective or
connected in-
correctly
Check differ-
ential pressure
sensor connec-
tion
A
A
E078
Impermissible
motor number
Internal elec-
tronics error
Contact cus-
tomer service
A
A
E096
Infobyte not
set
Internal elec-
tronics error
Contact cus-
tomer service
A
A
E097
Flexpump data
record missing
Internal elec-
tronics error
Contact cus-
tomer service
A
A
E098
Flexpump data
record invalid
Internal elec-
tronics error
Contact cus-
tomer service
A
A
E121
Motor PTC
short-circuit
Internal elec-
tronics error
Contact cus-
tomer service
A
A
E122
Interruption to
NTC power
element
Internal elec-
tronics error
Contact cus-
tomer service
A
A
E124
Interruption to
NTC electronic
module
Internal elec-
tronics error
Contact cus-
tomer service
A
A
Impermissible
combinatorics
E099
Pump type
Different pump
types have
been intercon-
nected
Contact cus-
tomer service
A
A
Table 26: Error codes
Additional explanations of error codes
Error E021:
Error “E021” indicates that the pump requires more power than is permitted. To ensure
that the motor and electronic module do not suffer irreparable damage, the drive pro-
tects itself by switching the pump off if an overload lasts more than 1 minute. The most
common causes of this error are a pump type of too small dimensions, especially when
pumping viscous fluids, or an excessive volume flow in the system. When this error code
is displayed, there is not an error in the electronic module.
Error E070; possibly combined with error E073:
If additional signal or control cables are connected to the electronic module, the effects
of EMC (immission/interference resistance) may interrupt communication. This results
in error code “E070” being displayed.
You can check this by disconnecting all communication cables installed by the cus-
tomer in the electronic module. If the fault no longer occurs, there may be an external
Содержание Yonos GIGA-N 125-5,5