Product description
en
Installation and operating instructions Wilo-Yonos GIGA-N
17
Example: Yonos GIGA-N 40/200-15/2-R1-P5
P5
Option:
empty = with spacer coupling
P5 = without spacer coupling (with standard coupling)
4.7
Technical data
Property
Value
Remarks
Speed range
750 ... 2900 rpm
380 ... 1450 rpm
Depending on pump type
Nominal diameters DN
32, 40, 50, 65, 80, 100, 125, 150 (dis-
charge side)
Pipe connections
Flanges PN 16
EN 1092-2
Permissible min./max. fluid temper-
ature
-20 °C ... +140 °C
Depending on the fluid
Ambient temperature min./max.
0 ... +40 °C
Lower or higher ambient temperatures
on request
Storage temperature min./max.
-20 °C ... +60 °C
Max. permitted operating pressure
16 bar
Insulation class
F
Protection class
IP55
Electromagnetic compatibility
Emitted interference in acc. with:
Interference resistance in acc. with:
EN IEC 61800-3:2018/IEC
61800-3:2017
Industrial environment (C2)
Sound-pressure level
1)
L
pA, 1m
< 83 dB(A) | ref. 20 µPa
Depending on pump type
Permissible fluids
2)
Heating water according to VDI 2035
Cooling/cold water
Water-glycol mixture up to 40% vol.
Standard version
Standard version
Standard version
Electrical connection
3~380 V -5 %/+10 %, 50/60 Hz
3~400 V ±10 %, 50/60 Hz
3~440 V ±10 %, 50/60 Hz
Supported mains types
3)
: TN, TT
Internal electric circuit
PELV, galvanically isolated
Speed control
Built-in frequency converter
Relative humidity
At T
ambient
= 30 °C: < 90 %, non-con-
densing
At T
ambient
= 40 °C: < 60 %, non-con-
densing
1)
Average value of the sound-pressure levels on a spatially rectangular measuring surface at a distance of 1 m from the
pump surface in accordance with DIN EN ISO 3744.
2)
For more information about permissible fluids, see the “Fluids” section on the next page.
3)
Electronic modules for IT networks are optionally available for motor power from 11 ... 22 kW. Compliance with the
specified values according to EN 61800-3 can only be guaranteed for the standard version of TN/TT networks. Non-ob-
servance can result in EMC faults.
Table 2: Technical data
Pumped fluids
Take account of the fact that water-glycol mixtures or fluids with a different viscosity
from pure water increase the power consumption of the pump. Only use mixtures with
corrosion protection inhibitors.
Observe relevant manufacturer specifications!
ƒ
The fluid must be sediment-free.
ƒ
The use of other fluids requires approval from Wilo.
ƒ
Mixtures with a proportion of glycol of > 10 % influence the flow calculation.
ƒ
In systems built according to the state of the technology, under normal system con-
ditions it can be assumed that the standard seal/standard mechanical seal is com-
patible with the fluid.
Special circumstances may require special seals, for example:
–
Solid materials, oils or EPDM-corrosive substances in the fluid,
–
air in the system etc.