Wilo Wilo-Drain SP Скачать руководство пользователя страница 34

ENGLISH 

8

 

3.3

 

SHORT TERM STORAGE 

Leave  piping  connection  caps  fastened  to  keep  dirt  and  foreign 
material out of pump casing during storage. 

 

If the pump will not be used immediately after delivery, it must be 
stored  in  a  temperate,  dry,  ventilated  location  and  away  from 

vibrations.  Turn  the  pump  shaft  at  intervals  (every  month)  to  avoid 
brinelling  of  the  bearings  and  the  seal  faces  from  sticking.  Close 
protective packing when done. 
If stored as described above, the pump can be stored up to 6 months. 
Consult WILO for preservative procedure when a longer storage period 
is required. 

3.4

 

HANDLING 

Depending on their design some pumps can fall over before they 
are definitively fastened to the floor. Take all necessary actions to 

ensure that no-one can be crushed while the equipment is moved. 

A  crane  must  be  used  to  lift  all  equipment  exceeding  25Kg. 
Palettes,  crates  or  boxes  can  be  moved  or  unloaded  by  using  a 

fork-lift  truck  or  a  hoist  depending  on  lifting  devices  available  on  site. 
Only  suitable  lifting  gear  and  load  carrying  equipment  with  valid  test 
certificates  and  adequate  lifting  capacity  for  the  loads  involved  should 
be  used  to  lift  and  carry  the  goods.  Only  authorized  personal  should 
proceed to pump transportation and they must respect local regulations. 
Weight of goods is indicated on the delivery note. 

Only  use  suitable  lifting  points  that  are  indicated  on  the 
equipment  and  respect  hereafter  lifting  and  transportation  

sketches. Pumps should never be lifted directly with slings. Hooks must 
be used and placed in dedicated lifting holes. Chose proper sling length 
or use a lifting beam. 
 
Lifting a close-coupled or a biblock pump : 

 

Lifting  a  pumpset  with  folded  base :      Lifting  a  pumpset  with  cast  iron 
base : 

 

 

Lifting a bareshaft pump : 

 

 
 

4

 

INTENDED USE 

S  pumps  are  designed  to  handle  non  viscous  fluids  with  particles 
content. 
The specific casing design ensures a quick and reliable selfpriming. Pump 
design  allows  a  long  lifetime  use,  even  when  run  in  the  harshest  duty 
conditions. Various materials, different types of shaft sealings and many 
motor  configurations  are  available  to  match  major  industrial  and  OEM 
needs. 
S  pumps  can  be  used  in  most  demanding  process  lines  or  on  building 
sites, in every  kind of industries for handling of effluents, condensates, 
sludge, … 
 

5

 

DESCRIPTION 

5.1

 

TYPE KEY 

Pump  description  is  engraved  on  pump  name  plate.  It  gives  a 
general description of pump design. The nameplate is attached to 

pump casing. 

 

Product information according description : 

EXAMPLE :  

SP

 

40

 

 

F

 

A

 

R

 

-

 

21

 

-

 

T

 

11

 

/

 

2

 

K

 

-

 

3B

 

 

1

 

 

2

 

3

 

4

 

 

5

 

 

6

 

7

 

 

8

 

9

 

 

10

 

SP

 :     

Pump product line : Wilo-Drain SP 

1 : 

(40)      Pump size 

2 :

 (F)  

Materials 

(see detail of pump parts in chapter « 5.2.1 Materials») 

-

 

F : Cast iron 

-

 

E : Cast iron casing and stainless steel impeller 

-

 

Z :  Cast  iron  casing  and  stainless  steel  or  bronze  impeller  +  zinc 
anode 

-

 

B : Bronze 

-

 

X : Stainless steel 

 

3

 : (A)  

Shaft sealing 

See details in chapter « 5.2.1 Materials » 

 

4

 : (R)  

Hydraulic variants 

R

 

Threaded ports  

With self regulated greasing cartridge 

S

 

Flanged ports 

With self regulated greasing cartridge 

T

 

Threaded ports  

Without self regulated greasing cartridge 

Flanged ports 

Without self regulated greasing cartridge 

Threaded ports  

With self regulated greasing car cutting device 

Flanged ports 

With self regulated greasing car cutting device 

Threaded ports  

With external Flushing 

Flanged ports 

With external Flushing 

 

 

 

 

 

 

 

Содержание Wilo-Drain SP

Страница 1: ...FR Notice de montage et de mise en service EN Installation and operating instructions Wilo Drain SP 4186313 Ed 02 2013 10 Wilo...

Страница 2: ......

Страница 3: ...FR Notice de montage et de mise en service Wilo Drain SP 4186313 Ed 02 2013 10 Wilo...

Страница 4: ...FRAN AIS 2...

Страница 5: ...p ratures du fluide 6 2 9 3 Risque d accumulation de m langes explosifs 7 2 9 4 Risque de fuites 7 2 9 5 Groupe complet 7 2 9 6 Groupe livr sans moteur sans instrumentation 7 2 9 7 Protecteur d accoup...

Страница 6: ...ctuer apr s d marrage 16 8 5 Mise hors service 16 8 6 Temps d amor age 16 9 Maintenance 17 9 1 G n ralit s 17 9 2 Programme d entretien et inspections p riodiques 17 9 2 1 Lubrification 17 9 2 2 Optio...

Страница 7: ...rmique etc Dommages mat riels Perte de la protection anti d flagrante Risque de pollution de l environnement 2 4 CONSIGNES DE SECURITE 2 4 1 CONSIGNES DE SECURITE POUR L UTILISATEUR INTERVENTION SUR L...

Страница 8: ...pe il est de la responsabilit de l int grateur de respecter toutes les r gles en vigueur pour pouvoir certifier son quipement CE La certification du groupe motopompe dans lequel la pompe sera int gr e...

Страница 9: ...toutes les r gles en vigueur pour pouvoir certifier l quipement complet dans la zone ATEX consid r e 2 9 7 PROTECTEUR D ACCOUPLEMENT Le protecteur d accouplement utilis en atmosph re explosible doit...

Страница 10: ...personnel qualifi et habilit peut proc der au levage tout en respectant les r glementations locales Le poids du groupe est indiqu sur le bordereau d exp dition Veiller n utiliser que les points de lev...

Страница 11: ...oir chapitre 5 1 d signation produit le tableau ci dessous vous donne la mati re des diff rents composants de la pompe Code Corps de pompe Roue Arbre chemise Plaques d usures F Fonte Fonte Inox Fonte...

Страница 12: ...nu 50Hz Service continu 40 OUI 45 OUI 50 OUI 60 Si d bit loin de Qopt ou si fluide abrasif passer sur une taille de pompe sup rieure 63 Si d bit loin de Qopt ou si fluide abrasif passer sur une taille...

Страница 13: ...RIDES L axe de la bride d aspiration est horizontal et la face de bride verticale L axe de la bride de refoulement est vertical et la face de bride horizontale 5 2 6 VALEURS ADMISSIBLES DES FORCES ET...

Страница 14: ...ol b tonn massif b ton poutrelles m talliques Le choix de ce support et son dimensionnement sont de la responsabilit de l utilisateur Il aura une influence sur le niveau de bruit et les vibrations ren...

Страница 15: ...ie habituellement disponible Utilisation d une r gle et d un pied coulisse Utilisation d un comparateur Lors du contr le du parall lisme au comparateur la valeur lue est gale deux fois la valeur du d...

Страница 16: ...nseill d installer une vanne d isolement cadenassable passage int gral au refoulement de la pompe Tuyauteries auxiliaires Dans la majorit des cas la pompe est mont e avec une garniture simple Si la po...

Страница 17: ...es isol s roulements sp cifiques ou de paliers isol s roulements standards 8 MISE EN SERVICE 8 1 AVANT LA MISE EN ROUTE Si la pompe est install e dans une zone potentiellement explosible ou pour le po...

Страница 18: ...pte de toute trace de produit pomp 8 6 TEMPS D AMOR AGE La tuyauterie d aspiration se vide entre deux d marrages Au d marrage la pompe ne d bite pas instantan ment mais apr s un temps variable de fonc...

Страница 19: ...ch it d arbre et la r gler pour les pompes quip es d un presse toupe tresses Contr ler l absence de fuite aux joints de pompe et de brides Contr ler le niveau et l aspect de l huile pour les paliers b...

Страница 20: ...et le joint 4510 9 3 1 3 DEMONTAGE COMPLET DU PALIER Version bride IEC 1 D visser les vis 6580 de fixation du moteur sur la lanterne IEC 2 D poser le moteur 8100 avec son demi accouplement 7200 2 3 R...

Страница 21: ...aux normes en vigueur pour le serrage de brides fontes ou acier Les valeurs de couple de serrage ci apr s sont donn es titre indicatif Vous pouvez obtenir les valeurs r elles en vous adressant notre H...

Страница 22: ...dans la boite bornes du moteur Fuite du corps de pompe de l tanch it d arbre ou de la conduite d aspiration Remplacer le joint de corps Contr ler l tanch it d arbre Contr ler l tat des joints des bri...

Страница 23: ...1 1 PLAN EN COUPE 12 1 2 NOMENCLATURE Rep re D signation 1100 Volute 1139 Bride aspiration 1221 Fond de corps Inox 1230 Trappe de visite 1381 Bride de refoulement 1915 Plaque d usure 2100 Arbre palier...

Страница 24: ...options ne concernent peut tre pas votre pompe Notre Service Pi ces de Rechange peut confirmer la nomenclature de la pompe gr ce au num ro de s rie disponible sur la plaque signal tique 12 4 PIECES D...

Страница 25: ......

Страница 26: ...24...

Страница 27: ...EN Installation and operating instructions Wilo Drain SP 4186313 Ed 02 2013 10 Wilo...

Страница 28: ...ENGLISH 2...

Страница 29: ...Specific marking instructions for ATEX 6 2 9 2 Fluid Temperature 6 2 9 3 Build up of explosive mixture 7 2 9 4 Preventing leakage 7 2 9 5 Complete unit 7 2 9 6 Pump unit delivered without motor withou...

Страница 30: ...ning checks 16 8 5 Shutdown 16 8 6 Priming time 16 9 MAINTENANCE 17 9 1 General information 17 9 2 Maintenance and periodic inspections schedule 17 9 2 1 Lubrication 17 9 2 2 Variant with galvanic ano...

Страница 31: ...al and chemical thermal risks Property damages Loss of ex proof protection Risk of environmental pollution 2 4 SAFETY INSTRUCTIONS 2 4 1 SAFETY INSTRUCTIONS FOR THE OPERATOR OPERATION ON THE PUMP SET...

Страница 32: ...instructions are fully respected 2 9 SECURITY INSTRUCTIONS TO BE APPLIED ON EQUIPMENTS USED IN POTENTIALLY EXPLOSIVE ATMOSPHERE This chapter contains operating instructions that have to be considered...

Страница 33: ...d used in a potentially ATEX atmosphere shall meet following requirements Consist of non sparking material e g brass Must be made of antistatic material Must be designed in such a way that the rotatin...

Страница 34: ...ling length or use a lifting beam Lifting a close coupled or a biblock pump Lifting a pumpset with folded base Lifting a pumpset with cast iron base Lifting a bareshaft pump 4 INTENDED USE S pumps are...

Страница 35: ...zinc anode Bronze or stainless steel Stainless Steel Bronze or stainless steel B Bronze Bronze Stainless Steel Bronze X SS 316 SS 316 SS 316 Stainless Steel Sealing The following table indicates mech...

Страница 36: ...nt is high choose bigger pump size 80 If flow much higher than QBEP or if abrasive content is high choose bigger pump size 83 If flow much higher than QBEP or if abrasive content is high choose bigger...

Страница 37: ...ontal 5 2 6 PERMISSIBLE FORCES AND MOMENTS No other stress than the one due to fastening of pipe and pump flanges together should apply No stress must be applied to pump casing by the pipe work A pre...

Страница 38: ...Check that there is ample overhead for lifting and that lifting devices are available 7 1 1 FOUNDATION Pump set can be installed on various types of foundations on a concrete ground on a foundation c...

Страница 39: ...ral types of flexible couplings can be used Refer to coupling operating instructions to know adjustment values and misalignment limits Several methods can be used to make coupling alignment Choice of...

Страница 40: ...ilter can be installed before the pump intake To ensure proper working of pump the equivalent exchange surface of the strainer should be 3 time the pipe sectional area Clogging state of filter straine...

Страница 41: ...eed should not fall under 40 of pump nominal speed to avoid any vibrations and an unstable flow The harmonic currents that are created by the VSD pass through motor ball bearings Standard ball bearing...

Страница 42: ...iary connected systems should be completely drained or otherwise protected For prolonged shut downs an adapted rust protective coating should be applied to the inside and outside of the pump Pumping e...

Страница 43: ...IONS SCHEDULE It is recommended to build up a maintenance and inspection plan to ensure a reliable use of pump and to reduce malfunctions hazards Following check points should be included in this main...

Страница 44: ...CAL SEAL HOUSING Close coupled variants 1 Remove motor fastening screws 6570 from motor 8020 2 Remove mechanical seal housing 4211 Variant with bearing bracket 1 Remove mechanical seal housing fasteni...

Страница 45: ...pled pump pump sets with elastic coupling Motor can be fitted with lifetime lubricated ball bearings identified ZZ or 2Z or greased Greasing nipples are located at the ball bearings and re greasing qu...

Страница 46: ...on pump casing gaskets on shaft sealing or on suction piping Replace casing seal s Check shaft sealing Check the state of the flanges seals Pump is not lifting liquid Air leaks into pump through mech...

Страница 47: ...drawing and bill of material is available upon request The demand should be sent to our Spare parts Dpt and should mention pump description and serial number Data are engraved on the pump name plate a...

Страница 48: ...acking rings Set of bearing bracket ball bearings Set of shaft bearing Set of motor ball bearings for frame size 90 Complete set of seals and gaskets Coupling elastic part s Automatic greasing cartrid...

Страница 49: ...ENGLISH 23...

Страница 50: ......

Страница 51: ......

Страница 52: ...4186313 Ed 02 2013 10 Wilo WILO SE Nortkirchenstrasse 100 44263 Dortmund Germany T 0231 4102 0 F 0231 4102 7363 wilo wilo com www wilo com...

Отзывы: