Manual: R4000-XX-X-000-X-X_EN
Release: 1.20
©Elotech GmbH
Seite 11 / 48
<- 6 zone controller
12/16-zone controller: (in conjunction with 12/16-
zone expansion module)
The structure is similar to the picture of the 8-zone
controller.
Below the zones are 2 buttons (+ / -) for switching
the zones (1 ... 8) to (9 ... 16) and back.
Monitoring 1 of zone 4 is active.
Zone 4 is set as the display zone.
Unit bar. Monitoring 1 is active.
Monitoring 2 of zone 8 is active.
At this point the signal has an enable function
.
Therefore
the
colour green was chosen.
Ramp is active.
Soft start
function
is active.
Auto tune is active.
Setpoint 2 is active. "SP2" in the header indicates that setpoint
2 is activated.
If setpoint 2 is set in a zone, this zone is set to this setpoint 2
when logic input In_1 is closed. Zones with setpoint 2 set to
"OFF" are not switched over.
Contact of Monitoring relay 1 is closed.
Contact of Monitoring relay 2 is open.
Tapping the area of the zone, here zone 2, leads to the next
menu. A grey frame and blue zone symbols show up while
pressing the key. Briefly pressing the key leads to the zone
overview. Holding down the key (>1s) leads to the main.