Manual: R4000-XX-X-000-X-X_EN
Release: 1.20
©Elotech GmbH
Seite 20 / 48
Window: Program controller Selection/Setting
This window gives an overview of the 8 control programs. One arrives on the Edit button in
the "Program controller graph" into this menu.
Select the program
The green frame shows the selected program.
Select a other program by pr and – keys.
Press the respective program button branches to
the setup menu of the program.
The name of the program can be changed in the
following window.
Setting the program properties
In this screen you can set the properties of the
program. You can also use the "Steps" button to
set the times and temperatures of the individual
steps.
The Name button is used to set the program name.
Use the "For Zone" key to define the zones in-
volved.
Continue if
Time expired
All steps are executed according to the predefined time
grid.
Temp. reached
After the ramp time has elapsed, the current step tem-
perature is controlled until all the relevant zones have
reached this setpoint. * The setpoint must be reached
up to + - 2K.
Program end
setpoint 1
After completion of the last step, the control setpoint is
further regulated. Normally setpoint 1.
Last setpoint
After the last step has been completed, the temperature
of the last step is further regulated.
Repeat
After the last step has been completed, step 1 is started
again.
Number of
steps
1 … 8
Count of steps.