3
Type Code
If 12 or 16 zones are required, an 8-zone controller and an expansion module R4010 (4 or 8
zones) must be ordered.
The E-bus on the R4000 is required for communication with the R4010.
If the required controller already has a fieldbus interface, then the E-bus interface is already
available.
If no fieldbus interface is required, key 90 (E-bus) must be selected for the fieldbus.
R4000 - X - Z - Y - 000 - DD - 5
Power Supply
5 24 VDC
Fieldbus Interface
00 No
03 RS 232-C + RS 485 + 0/20mA TTY (incl. E-Bus)
09 Profibus-DP (incl. E-Bus)
90 E-Bus to connect the extension module R4010
Heater Current Monitoring
0 No
5 Yes (Logic outputs only)
Zones
1 zone
2 2 zones
4 4 zones
6 6 zones
8 8-zones
Versions
0 Output each zone: 1x Logic & 1x Relay (standard)
1 Output each zone: 1x Logic & 1x 0-10V o. 0/4-20mA
12 and 16 zones: see note below
DD