Specifications
Model IL-10
{-10 ... +85°C with FEP-cable}
{-14 ... +185 °F with FEP-cable}
Storage
3)
-10 ... +60 °C
-14 ... +140 °F
3)
Also complies with EN 50178, Tab. 7, Operation (C) 4K4H, Storage (D) 1K4,
Transport (E) 2K3
4)
Other temperature ranges are possible, depending on the electrical connection;
see EC-type examination certificate and table page 13)
Compensated temp range
0 ... +50 °C
32 ... +122 °F
Temperature coefficients within
compensated temp range
Mean TC of zero
% of span
≤
0.2 / 10 K (< 0.4 for pressure range
≤
250 mbar)
Mean TC of range
% of span
≤
0.2 / 10 K
Ex-protection
ATEX
Category
5)
1G (IIA), 1/2 G, 2G, 1D, 1/2D, 2D, M1, M2
Ignition protection type
EEx ia I/II C T4, EEx ia I/II C T5, EEx ia I/II C T6
Ex-protection
FM, CSA
Class I, II and III
Ignition protection type
Instrinsic safe Class I, II, III Division 1,
Group A, B, C, D, E, F, G and Class I, Zone 0 AEx ia II C
5)
Read
the operating conditions and safety-relevant data in the
EC-type
examination certificate in any cas
e (DMT 00 ATEX E 045 X)
CE- conformitiy
EMC directive
2004/108/EEC, EN 61 326 Emission (Group 1, Class B) and Immunity
(industrial locations)
ATEX-Directive ATEX of equip-
ment intended for use in potenti-
ally explosive atmospheres
94/9/EC
Approval German Lloyd GL
Environmental Category C, F, EMC 1
RF-immunity
V/m
10
Burst
kV
4
Wiring protection
Short-circuit proofness
Sig+ towards UB-
Reverse polarity protection
UB+ towards UB-
Electrical connections Category
Ambience-/ Medium tempera-
ture range
PUR-cable
1 G (IIA), 2 G (IIA), M1, 1 D, 2 D
-10 ... +60 °C
14 ... +140 °F
FEP-cable
1 G (IIA)
-30 ... +60 °C
-22 ... +140 °F
2 G (IIA), M1
-30 ... +105 °C
-22 ... +221 °F
1 D, 2 D
-30 ... +80 °C
-22 ... +176 °F
Specifications
Model IL-10
Weight
kg
Approx. 0.2
Cable
»
kg
Approx. 0.08 per m cable
7. Starting, operation
GB
{ } Items in curved brackets are optional extras for additional price.
Functional test
Observe the ambient and working conditions outlined in section 7
„Technical data.
Please make sure that the level probe is only used within the over load
threshold limit at all times!
When touching the level probe, keep in mind that the surfaces of the instru-
ment components might get hot during operation.
The output signal must be proportional to the pressure. If not, this might point to a
damage of the diaphragm. In that case refer to chapter 9 „Troubleshooting“.
7. Starting, operation / 8. Maintenance, accessories
GB
8. Maintenance, accessories
Accessories:
For details about the accessories, please refer to WIKA‘s price list, WIKA‘s
product catalog on CD or or contact our sales department.
WIKA level probes require no maintenance.
Have repairs performed by the manufacturer only.
Permissible temperature ranges depending on electrical connections
Warning