With the [Edit] tab selected (Figure 7-47 Programs- Edit) the operator can edit existing programs or
create steps in new ones. Pressing a Command or Data point will present the available commands, or
a data entry selections in the side bar. The [Insert] and [Delete] buttons allow insertion and deletion of
lines. Selection of commands and data in each sequential line will create a draft of resulting command
sequence in the selected program, upon exiting the edit mode with the back button [
] the
instrument will ask “Replace old values?’. Pressing the [
] will accept the changes, pressing the [
] will revert back to the old program. A list of available commands, data values and their functions
are listed in Table 4 on the following page.
Figure 7-47 Programs- Edit
Table 4 Sequence Commands
Feature
DELAY
Delays for time = 1 to 3600 seconds (Numerical Entry)
MODE
Sets the control mode (Measure, Control or Vent)
PTYPE
Sets the pressure type (Gauge or Absolute)
RSERPT
Sets the rate setpoint in current units (Numerical Entry)
RUNITS
Sets the rate denominator time unit (min or sec)
SENSOR
Sets the active sensor (1 , 2 or 3)
SEQUSTART
Starts the sequence from the beginning (None)
SETPOINT
Sets the control setpoint for the instrument (Numerical Entry)
SETPOINT%
Sets the control setpoint in % of current range (Numerical Entry)
WAIT
Waits for a manual input or stable condition (Stable or Input)
Favorites
The Setup [
] / [Applications] / [Favorites] screen is used to select programs that will appear in the
main screen when the Favorites [
] icon is pressed. The current list of favorites is shown in figure
7.5.2.5.6 on the left. Press one of these and then press the available programs on the right to update
the current favorites list with that program.
Figure 7-48 Favorits