Wieland
podis
system
Manual V 1.03 / ref. no. 00.000.0059.0 / 28.03.2001
Example 2: Stepwise acceleration with retention at one
speed, only clockwise rotation, ramp unchanged
Clockwise speed
Anti-clockwise speed
Explanation of example 2
Control bits
Range Enable Right Left Ramp Speed
Motor
Explanation
[K] 1 1
0
5 0
Stationary Enable
and
clockwise
rotation
HIGH,
ramp preset: motor is stationary as a
speed has not yet been indicated
[L]
1
1
0
5
50
Accelerates right Motor accelerates with preset ramp
until it reaches indicated speed
(in this case 50dec = 12.5 Hz)
[M] 1 1
0
5
50
Rotates
clockwise at a
constant speed
Speed is reached, motor speed
remains unchanged
[N] 1 1
0
5
200
Further
accelerates right
Motor accelerates further with preset
ramp until it reaches indicated speed
(in this case 200dec = 50 Hz, same
ramp as for acceleration)
[O] 1 0
0
5
200
Rotates
clockwise at a
constant speed
Speed is reached, motor speed
remains unchanged
[P] 1 0
0
5
150
Gradually
slows
down until it
reaches given
speed
Motor brakes with preset ramp until it
reaches a standstill (in this case
150dec = 37.5 Hz, same ramp as for
acceleration)
[Q] 1 1
0
5
150
Rotates
clockwise at a
constant speed
Speed is reached, motor speed
remains unchanged
[R]
1
1
0
5
0
Slows down
Motor brakes with preset ramp until it
reaches a standstill (same ramp as for
acceleration)
[S] 1 1
0
5 0
Stationary Enable
and
clockwise
rotation
HIGH,
ramp preset: motor is stationary as no
speed has been indicated
Notes regarding example 2
•
Braking with the set ramp until the motor reaches a standstill
is only possible if the speed value 0 (zero) is preset while the
motor is in motion (range [R]).
•
If the enable or direction of rotation is set to LOW, the motor
stalls abruptly – regardless of the ramp.
•
The ramp can be modified during operation. It is therefore
possible to set different acceleration and braking times (e.g.
acceleration in 6 seconds, braking in 3 seconds).
Bild: 00101792