background image

CONNECTION CABLE

INSTRUCTIONS

Thank you for purchasing this Icom product.

The OPC-2389 connection cable is used to connect a 

serial communication device to the VE-PG3 or VE-PG4.

READ ALL INSTRUCTIONS

 carefully and completely 

before using the cable.

Turn OFF the all devices that are connected to the VE-PG3 or VE-PG4, and then connect the OPC-2389, as shown below.

1

CONNECTING THE OPC-2389

CAUTION

• Verify that both the repeater and the VE-PG3 or VE-PG4 are turned OFF when connecting or disconnecting the cable.

• Hold the connector body when connecting or disconnecting them.

• Never bend or pinch the cable.

 • Never place a heavy object on the cable.

• Never touch the cable with wet hands.

• Always connect the cable correctly. An incorrect connection could damage the VE-PG3 or VE-PG4 and/or the connected device.

• Never add a pulling tension to the cable.

•  Never use the OPC-2389 with any device other than VE-PG3 and VE-PG4.  

Some serial communication devices may not be used.

VE-PG4 (Rear view)

OPC-2389

• This is an example of connecting a serial communication device to the [EXT1] port.

A1

~

A4

A1

~

A4

B1

~

B4

B1

~

B4

C1

~

C4

C1

~

C4

A1

~

A4

A1

~

A4

B1

~

B4

B1

~

B4

C1

~

C4

C1

~

C4

A1

~

A4

A1

~

A4

B1

~

B4

B1

~

B4

C1

~

C4

C1

~

C4

A1

~

A4

A1

~

A4

B1

~

B4

B1

~

B4

C1

~

C4

C1

~

C4

B C

Be  sure  to  insert  the 

connectors top side up.

Bottom

To a serial communication device

Top

B

1 2 3 4

q

t r e w

y

o i u

B C

When other cables are connected, you can 

use  needle-nose pliers to carefully insert or 

remove connectors.

VE-PG4 (Rear view)

VE-PG4 (Rear view)

Needle-nose pliers

Needle-nose pliers

NEVER pull the connector by holding the 

cable. This will damage the cable. 

*If the cable becomes damaged, replace 

the connector(s). See “REPLACING THE 

CONNECTOR” on the reverse side for  

replacement details.

Connector 

body

Connector 

body

REPLACING THE CONNECTOR

If the cable becomes damaged, replace the connector(s). Make wire connections as described below.

• Spare connectors*

1

 are supplied with the VE-PG3 or VE-PG4.

*

1

 Manufacturer: DDK.   Name: 232D-04S1B-DA5-FA

The connector has two parts: a black base and a clear insert. 

DO NOT

 lock the connector parts before inserting all wires.

Insert the wires into the holes 

according to the assigned pin 

numbers.

1

Press the clear insert down 

until it locks in place.

2

Connector

(Supplied with 

 the VE-PG3 

 or VE-PG4)

Connector

(Supplied with 

 the VE-PG3 

 or VE-PG4)

The wires for each hole 

are assigned by color. See 

the illustration below. 

OPC-2389

To the serial communication device 

B C

q

t r e w

y

o i u

Pin No.

Orange

Orange

Blue

Blue

Yellow

Yellow

Gray

Gray

B

Connector top (Expanded view)

Brown

Brown

Green

Green

Purple

Purple

Red

Red

C

1

2

3

4

1

2

3

4

OPC-2389 connection and wires assignment

RECOMMENDATION

If reconnecting is re-

peated about 30 times, 

cut the wires*

*

3

 near 

the connector and re-

place the connector.

*

2

  Remove the cable from the VE-PG3 or 

VE-PG4, before cutting the wires.

*

3

  DO NOT cut the wires too short. Other-

wise it will be difficult to reconnect them 

to the VE-PG3 or VE-PG4.

1

2

3

4

•  After the insert is locked, it is 

impossible to release it again.

Icom, Icom Inc. and the Icom logo are registered trademarks of Icom Incorporated (Japan) in Japan, the United States, the 

United Kingdom, Germany, France, Spain, Russia, Australia, New Zealand, and/or other countries.

A7471X-1J-1

Printed in Japan

© 2018 Icom Inc.

1-1-32 Kamiminami, Hirano-ku, Osaka 547-0003, Japan

Отзывы: