MOUNTING THE EVAPORATOR UNITS
NOTE:
You are
REQUIRED
to use only the mounting locations provided. These locations
ensure that the installer will not drill into any copper or electrical wiring within the system.
It is vital that the units be set apart and oriented so that the return air
from one unit does not recirculate into the supply air of the other unit.
NOTE:
If installing the units without attic access, perform steps 5-2
1
prior to steps 3-4.
1. Display cable
2. Power and thermostat wires
3. Drain line
4. Line set
Routed Items:
Line Set / Drain Line
Display, Power. and
Thermostat Wires
3.
Secure the mounting bracket to the
primary
evaporator unit using the twelve (12) supplied 3/8” Phillips pan-head
screws
.
4.
Secure the
primary
evaporator unit’s mounting bracket to the opening using the twelve (12) supplied 21/2” Phillips-
head screws.
Page 13
08/04/21
Содержание Twin Ceiling Mount H.E. CM12000
Страница 29: ...CEILING MOUNT WIRING DIAGRAM KDT Page 27 08 04 21...
Страница 30: ...CEILING MOUNT WIRING DIAGRAM 24V Page 28 08 04 21...
Страница 31: ...CONDENSING UNIT WIRING DIAGRAM Page 29 08 04 21...
Страница 61: ...WhisperKOOL 1738 E Alpine Ave Stockton CA 95205 1 800 343 9463 www whisperkool com...