Correcting Warnings
Although a warning can be cleared without the physical cause being first removed, it is
recommended that the cause be determined and removed at the earliest opportunity. Warnings
are indicated by a flashing
FAULT
indicator. No error message is displayed.
83
Battery overtemp
Likely cause:
Battery bank temperature too high for safe charging.
Recommended Action:
Check battery bank connections and ventilate battery bank
compartment. Restart.
84
Clamp failed off
Likely cause:
Abnormal electrical condition, possibly resulting in raised battery
voltage.
Recommended Action:
Attempt to restart, contact an authorised WhisperGen service
agent if problem reoccurs.
85
High batt volts
Likely cause:
Battery bank voltage above normal charging limits.
Recommended Action:
Check settings of any parallel charger connected to the battery
bank. Restart.
90
Clamp control flt
Likely cause:
WhisperGen unable to maintain correct battery charging
voltage.
Recommended Action:
Attempt to restart, contact an authorised WhisperGen service
agent if problem reoccurs.
92
ParChg V too high
Likely cause:
WhisperGen operating voltage has gone too high, in an effort to
avoid conflict with a parallel charger.
Recommended Action:
Check voltage settings of other chargers connected to the
battery bank. Restart.
Code
Likely Cause and Recommended Action
102
Likely cause:
Exhaust gas hotter than normal, possibly due to low engine gas pressure.
Recommended Action:
Attempt to restart, contact an authorised WhisperGen service agent if problem
reoccurs.
Code
Error Message
Likely Cause and Recommended Action
When remedying WhisperGen warnings, please follow the
recommendations in this manual otherwise, you may injure yourself and
the warranty will be void. If the recommended action does not remedy the
warning, contact your authorised WhisperGen service agent.