R
28
Auto-Charging the Battery Bank
You can set the WhisperGen to automatically start and charge the battery bank when the battery
bank charge level is low.
To set the WhisperGen to auto-charge the battery bank:
1. Access the
User Menu
on the control panel – follow steps 1 to 3 of the procedure outlined in
section entitled Setting the Maximum Run Time.
2. Press
∨
to scroll down to
Auto-charge.
3. Press
>
to begin editing the auto-charge setting.
4. Press
∧
to select
ON
. The
AUTOCHARGE
indicator lights up.
5. Optional: press
<
repeatedly to return to the default display. You can also let the default
display re-appear automatically by allowing a few minutes of inactivity on the control panel.
R
FAULT
AUTOCHARGE
EXT CONTROL
HEAT MANAGE
STOPPING
RUNNING
STARTING
STANDBY
STOP
START
WTL0006
Auto-charge
R
FAULT
AUTOCHARGE
EXT CONTROL
HEAT MANAGE
STOPPING
RUNNING
STARTING
STANDBY
STOP
START
WTL0006
Auto-charge ON