8. Insert the new evaporator with the gasket into the burner and secure the four screws.
9. Check that the FID slides freely into the burner. If necessary, loosen the four evaporator
screws and readjust the position of the evaporator before re-tightening them.
10. Refit the glow plug.
11. Reconnect the fuel line to the evaporator. Finger tighten the nut against the shoulder. Using a
spanner tighten ¾ turn only.
12. Ensure that there is no leakages.
13. Refit the FID.
14. Bleed the fuel line. Refer to section entitled - Bleeding the Fuel Line.
15. Replace the enclosure lid.
16. Turn on the WhisperGen fuel valve.
The WhisperGen may now be started as required. The old evaporator can be returned to your
authorised WhisperGen service agent for servicing.
The evaporator should be serviced by an authorised WhisperGen service
agent only. Do not attempt to do it yourself.
It is advisable to keep a spare evaporator with the WhisperGen at all
times.