8. Press
>
to display the third item on the Installation Menu, Fuel Bleed.
9. Press
>
to begin editing the fuel bleeding setting.
10. Press
∧
to select
ON
. Fuel will be bled through in pulses for 60 minutes. You can stop the fuel
pump at any time by pressing
∨
. At least twice the volume of fuel in the entire fuel line
connecting the fuel tank to the evaporator must be bled. For example, if the fuel line measures
3mm in inner-diameter and 5m in length, then 70ml of fuel must be bled.
11. Optional: press
<
repeatedly to return to the default display. You can also let the default
display re-appear automatically by allowing a few minutes of inactivity on the control panel.
12. Reconnect the fuel line to the evaporator. Finger tighten the nut against the shoulder. Using a
spanner tighten ¾ turn only.
13. Ensure that there is no leakages.
14. Replace the enclosure lid.
The WhisperGen may now be started as required.
R
FAULT
AUTOCHARGE
EXT CONTROL
HEAT MANAGE
STOPPING
RUNNING
STARTING
STANDBY
STOP
START
WTL0006
Fuel Bleed
R
FAULT
AUTOCHARGE
EXT CONTROL
HEAT MANAGE
STOPPING
RUNNING
STARTING
STANDBY
STOP
START
WTL0006
Fuel Bleed ON