Displaying System Information
Available Information
The control panel displays information regarding the status of the WhisperGen system. The
following information, structured as shown in section entitled Quick Reference - Information
Structure, may be obtained from the control panel:
Default Display
Parameter
Meaning
Typical Range
Battery Volts
The voltage across the terminals of the
battery bank.
12V battery bank: 9.5 to 15.5
Volts.
24V battery bank: 19.0 to 31.0
Volts.
Battery Amps
The net quantity of electric current in
Amperes, flowing through the battery
bank. Positive values indicate charging
and negative values discharging.
-600 to 200A.
Batt Amp-hrs
The state of battery bank discharge in
Ah. A fully charged battery bank is
assigned zero Ah.
-700 to 100Ah.
Battery Watts
The quantity of electrical power in Watts
supplied to the battery bank. Positive
values indicate charging and negative
values discharging.
-7000 to 1000 Watts.
Gross Watts
The gross electrical power in Watts,
from the WhisperGen generator before
power to auxiliary devices such as the
air blower and pumps.
200 to 1000 Watts.
Runtime (Min)
The total operating time in minutes
since starting.
0 to 999,999 minutes.
Hour Meter
The cumulative number of hours of
operation since the WhisperGen was
first commissioned. The WhisperGen
must be serviced by an authorised
WhisperGen agent every 12 months or
every 2000 hours of operating time,
whichever comes first.
0 to 999,999 hours.
# Of Starts
The cumulative number of times the
WhisperGen has started since it was
first commissioned.
0 to 999,999.
Warning Code
The code of the prevailing warning, if
there is one. A flashing
FAULT
indicator
indicates the presence of a warning.
The flashing will stop if the cause of the
warning disappears.
100 to 199.