R
16
Operation
Introduction
This section outlines the procedure for operating your WhisperGen. It will show you how to:
•
Start and stop the WhisperGen;
•
Charge the battery bank;
•
Manage heat generation;
•
Clear faults and warnings;
•
Adjust the contrast of the LCD; and
•
Display and edit system parameters of the WhisperGen.
Installing the WhisperGen
To install the WhisperGen, contact your authorised WhisperGen service agent. The contact
details for your authorised WhisperGen service agent appear at the back of this manual.
Quick Reference - Operating Options
Depending on the options selected, the WhisperGen may stop running before or after the battery
bank is charged, as shown in the table below.
In all cases, the WhisperGen can be stopped at any time by pressing
STOP
on the control panel.
*
In
this mode, the WhisperGen will run for at least one hour.
WhisperGen
starting method
Heat Manage ON
Heat Manage OFF
Max Run Hours
< 25
Max Run Hours
= 25
Max Run Hours
< 25
Max Run Hours
= 25
Manual start
Stops when
Max
Run Hours
value
is reached, even if
the battery bank
is not yet fully
charged.
Continues
running until
stopped by the
user.
Stops when the
battery bank is
charged or when
Max Run Hours
value is reached,
which ever comes
first.
Continues
running until the
battery bank is
charged, then
stops.
Remote switch
start with
Ext Cont
Mode
set to
1
Remote switch
start with
Ext Cont
Mode
set to
2*
Continues
running until
stopped by the
user or remote
switch.
Auto-charge
start Stops when the battery bank is charged, regardless of
Max Run Hours
and
Heat Manage
settings.
WTL0000
You should read and understand all safety precautions before
operating your WhisperGen.
The WhisperGen must be installed by an authorised WhisperGen
service agent. If you install the WhisperGen yourself, the warranty
will be void. Incorrect installation may damage the WhisperGen and
property, and/or cause personal injury.