Managing Heat Generation
Setting the Coolant Temperature
Whenever it is running, the WhisperGen regulates the temperature of the coolant circulating
through it. The coolant is used for space and domestic water heating. By default, the temperature
of the coolant is maintained at approximately 60°C. You may however set the coolant temperature
to any temperature from 45°C to 70°C.
To set the temperature of the coolant:
1. Access the
User Menu
on the control panel – follow steps 1 to 3 of the procedure outlined in
section entitled Setting the Maximum Run Time.
2. Press
∨
to scroll down to
Temp Setpoint
.
3. Press
>
to begin editing the coolant temperature setting.
4. Press
∧
or
∨
to select the coolant temperature. The values shown on the control panel are in
°C.
5. Optional: press
<
repeatedly to return to the default display. You can also let the default
display re-appear automatically by allowing a few minutes of inactivity on the control panel.