4-8
n
HybridCare™ Dryer with Heat Pump Technology
COMPONENT ACCESS
To Remove the Moisture Sensor
1.
Unplug dryer or disconnect power.
2.
Perform the procedures on page 4-4, “Removing the Top
Panel” and “Removing the Console” prior to performing
the following steps.
3.
Perform the procedures on page 4-7, “Removing the Front
Panel” prior to performing the following steps.
4.
Disconnect Moisture Sensor connector (see Figure 1).
Moisture Sensor
Connector
Figure 1
Removing the Moisture Sensor
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Failure to do so can result in death or
electrical shock.
Replace all parts and panels before operating.
5.
Remove two (2) 1/4” hex-head screws securing the Outlet
Grill & Housing Assembly to the front bulkhead (see
Figure 2).
6.
Lift up the Outlet Grill & Housing Assembly from the
bulkhead (see Figure 2).
Outlet Grill &
Housing Assy
Remove 2 Hex
Head Screws
Moisture Sensor
M/F Connectors
Figure 2
7.
Separate the two halves of the Outlet Grill & Housing
Assembly to access and remove the moisture sensor (see
Figure 3).
Figure 3
Sensor Connector
Sensor Tabs
Содержание WED99HEDC0
Страница 12: ...1 8 n HybridCare Dryer with Heat Pump Technology GENERAL INFORMATION Notes ...
Страница 26: ...2 14 n HybridCare Dryer with Heat Pump Technology OPERATION Notes ...
Страница 48: ...3 22 n HybridCare Dryer with Heat Pump Technology INSTALLATION Notes ...
Страница 68: ...4 20 n HybridCare Dryer with Heat Pump Technology COMPONENT ACCESS Notes ...
Страница 98: ...6 22 n HybridCare Dryer with Heat Pump Technology TESTING Notes ...
Страница 100: ...W10764068A HybridCare Duet Dryer with Heat Pump Technology ...