TESTING
HybridCare™ Dryer with Heat Pump Technology
n
6-19
For Service Technician Use Only
DANGER
Electrical Shock Hazard
Only authorized technicians should perform
diagnostic voltage measurements.
After performing voltage measurements,
disconnect power before servicing.
Failure to follow these instructions can result in
death or electrical shock.
TEST #8: Drum LED
This test is performed if the drum LED does not light.
1. Pressing the
DRUM LIGHT
button on the console should
toggle the button indicator on and off (and the drum LED
on and off).
¾
If the button indicator toggles on and off, go to step 2.
¾
If the button indicator does not turn on, go to TEST #6
– “Some buttons do not light,” page 6-17.
2. Unplug dryer or disconnect power.
3. Remove the top panel to access CCU and user interface
(UI).
4. Verify the drum LED connector
J11
(see wiring diagram,
page 23) is securely connected to the UI.
5. Check harness and inline connections between the drum
LED and UI.
¾
If the harness and connections are good, go to step 6.
¾
If not, repair or replace as needed.
6. Unplug the drum LED connector J11 (see wiring diagram,
page 6-3 and strip circuit at left) from the UI.
7. With a multimeter set to milliamps, connect multimeter to
UI connector J11, pins 1 and 3. Plug in dryer or reconnect
power. Press the
DRUM LIGHT
button on the console until
the button indicator is on. Measure the current across
UI connector J11, pins 1 and 3. If the drum LED driver
is working properly, there should be a measurement of
150–370 mA.
¾
If the current is present, unplug dryer or disconnect
power and replace the drum LED.
¾
If the current is not present, unplug dryer or disconnect
power and replace the UI.
8. Reassemble all parts and panels.
Figure 2 - Drum LED
Figure 1 - Drum LED Connector on UI
Drum LED Connector
DRUM LED STRIP CIRCUIT
USER INTERFACE
DRUM LED CIRCUIT
J11-1
R
BK
R
J11-2
BK
DRUM LED
Содержание WED99HEDC0
Страница 12: ...1 8 n HybridCare Dryer with Heat Pump Technology GENERAL INFORMATION Notes ...
Страница 26: ...2 14 n HybridCare Dryer with Heat Pump Technology OPERATION Notes ...
Страница 48: ...3 22 n HybridCare Dryer with Heat Pump Technology INSTALLATION Notes ...
Страница 68: ...4 20 n HybridCare Dryer with Heat Pump Technology COMPONENT ACCESS Notes ...
Страница 98: ...6 22 n HybridCare Dryer with Heat Pump Technology TESTING Notes ...
Страница 100: ...W10764068A HybridCare Duet Dryer with Heat Pump Technology ...