6-16
n
HybridCare™ Dryer with Heat Pump Technology
TESTING
For Service Technician Use Only
TEST #5a: Adjusting Customer-Focused
Dryness Level
NOTE:
If the customer complains about the clothes being less
dry or more dry than desired and the moisture sensor passes
TEST #5: Moisture Sensor, step 2, the total dry time can be
lengthened or shortened by changing the Customer-Focused
Dryness Level from “
1
” (standard auto cycle) to a “
2
” (15%
more drying time), “
3
” (30% more drying time), “
4
” (15% less
drying time), or “
5
” (30% less drying time) auto cycle.
1. In standby mode (dryer plugged in but not powered up),
press and hold the
DRYNESS LEVEL
button for approximately
3 seconds. The dryer will beep and “
CF
” is displayed followed
by the current dryness setting on the 7-segment display. The
factory default value is “
1
”.
2. Pressing the dryness level button cycles the dryness setting
between 1, 2, 3, 4, and 5 in that order, starting at the current
setting. The new setting is displayed in the 7-segment display.
3. With the display showing the desired dryness setting, press
the
START
button to save the drying mode and exit to standby
mode (the START button in this mode does not start a drying
cycle). The result will be stored in EEPROM of the CCU and will
be retained after a power loss.
NOTE:
If there is no user activity for 20 seconds, or a button
other than START or DRYNESS LEVEL is pressed, the dryness
setting is reverted back to its previous setting.
4. Press the
POWER
button at any time to cancel changes and
exit from this mode.
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Failure to do so can result in death or
electrical shock.
Replace all parts and panels before operating.
3$*(
FOR SERVICE TECHNICIAN’S USE ONLY
DO NOT REMOVE OR DESTROY
STRIP CIRCUITS
MOTOR CIRCUIT
HEATER
THERMISTORS (COMPRESSOR/OUTLET)
MOISTURE SENSOR
L1
BK
P9-1
K1
MOTOR RELAY
CYCLE CONTROL UNIT
LBU
LBU
4M
DRIVE MOTOR
1/3 HP
MAIN
START
5M
3M
6M
2M
1M
See Heater Circuit
W
BU
N.O.
DOOR
SWITCH
W
N
P9-2
CENTRIFUGAL
SWITCH
BU
THERMAL
PROTECT
LBU
W
P14-1
COMPRESSOR
THERMISTOR
CYCLE CONTROL UNIT
PK
OUTLET
THERMISTOR
P14-3
10K
Ω
COMPRESSOR TEMP THERMISTOR
OUTLET TEMP THERMISTOR
R-W
10K
Ω
V
COMPRESSOR
THERMISTOR RTN
CYCLE CONTROL UNIT
OUTLET
THERMISTOR RTN
Y
P14-2
P14-6
CYCLE CONTROL UNIT
P13-1
BK
MOISTURE SENSOR
CYCLE CONTROL UNIT
MOISTURE SENSOR RTN
MOISTURE SENSOR
P13-2
P8-2
CHASSIS GND
Y-R
MOV
MOV
BK
R
G-Y
G-Y
G-Y
CHASSIS GND
Figure 8 - Strip circuits.
5M
3M
6M
2M
1M
CENTRIFUGAL SWITCH
See
Motor
Circuit
HEATER
R
R
V
V
V
L2
R
HIGH LIMIT
THERMOSTAT
L1
BK
RELAY K3
CYCLE CONTROL UNIT
N.O.
COM1
THERMISTORS STRIP CIRCUIT (refer to page 6-14 for diagnostics)
Содержание WED99HEDC0
Страница 12: ...1 8 n HybridCare Dryer with Heat Pump Technology GENERAL INFORMATION Notes ...
Страница 26: ...2 14 n HybridCare Dryer with Heat Pump Technology OPERATION Notes ...
Страница 48: ...3 22 n HybridCare Dryer with Heat Pump Technology INSTALLATION Notes ...
Страница 68: ...4 20 n HybridCare Dryer with Heat Pump Technology COMPONENT ACCESS Notes ...
Страница 98: ...6 22 n HybridCare Dryer with Heat Pump Technology TESTING Notes ...
Страница 100: ...W10764068A HybridCare Duet Dryer with Heat Pump Technology ...