4-15
REMOVING THE AC LINE FILTER CAPACITOR
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
WARNING
NOTE:
Sharp edges may be present.
1.
Unplug the microwave oven or disconnect
the power.
2.
Remove the air grille from the unit (see
page 4-11 for the procedure).
3.
Remove the control panel assembly (see
page 4-12 for the procedure).
4.
Discharge the 1100 W inverter
(perform
steps 3 and 4 on page 4-20).
5.
Remove the AC line filter capacitor from
the cooling fan motor and cut the wires
from the capacitor leads.
AC Line Filter Capacitor
Cut Both Wires
6.
Splice the wires coming from the new
capacitor to the cut harness wires, and
twist a pair of wire nuts over the ends of the
cut wires.
7.
Use a large bead of Selastic and adhere
the capacitor to the fan.