![Western Global FuelCube FCP1000 Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/western-global/fuelcube-fcp1000/fuelcube-fcp1000_operators-manual_962642025.webp)
21
TROUBLESHOOTING
The
FUEL
CUBE
TM
is a double walled tank for storage, dispensing and distribution of fuel. It is
a simple and reliable system that requires minimal maintenance.
In the following section, we have listed many of the problems, causes and solutions to the
problems that you may encounter.
If you encounter a problem that is difficult to solve, even after having read through this trouble
shooting section, please call your local Western distributor or dealer. Before you call, please
have this
Operator’s Manual
from your unit and serial number ready.
Pump will not run.
No power.
Connect power wires to 12
volt power source.
Pump off.
Turn pump on.
Diesel fuel in interstice.
Loose fitting.
Tighten fitting.
Leaking coupler.
Replace coupler.
Over-filling tank.
Watch dip stick when filling.
Do not over-fill tank.
Water in the interstice.
Leaving hatch lid open to
weather.
Remove water and keep
hatch lid closed.