![Western Digital 1EX1231 Скачать руководство пользователя страница 287](http://html1.mh-extra.com/html/western-digital/1ex1231/1ex1231_user-manual_960951287.webp)
User Guide
4. Management
4.10 Daisy Chaining
Four Enclosures: Two Hosts with Two HBAs
Source Device
Destination Device
Host1: P1
Enclosure1: IOMA, A6
Host1: P2
Enclosure4: IOMB, B1
Host1: P3
Enclosure1: IOMA, A4
Host1: P4
Enclosure4: IOMB, B3
Host2: P1
Enclosure1: IOMB, B1
Host2: P2
Enclosure4: IOMA, A6
Host2: P3
Enclosure1: IOMB, B3
Host2: P4
Enclosure4: IOMA, A4
Enclosure1: IOMA, A1
Enclosure2: IOMA, A2
Enclosure2: IOMA, A1
Enclosure3: IOMA, A2
Enclosure3: IOMA, A1
Enclosure4: IOMA, A2
Enclosure1: IOMB, B5
Enclosure2: IOMB, B6
Enclosure2: IOMB, B5
Enclosure3: IOMB, B6
Enclosure3: IOMB, B5
Enclosure4: IOMB, B6
4.10.4
Cabling for Daisy Chaining
Note:
The CMA should be installed before installing cabling.
Step 1 :
Choose a configuration from the
sections. The configuration choice should be made
based on the number of hosts being connected to the enclosure, the number of HBAs in each
host, and how many enclosures will be daisy chained together.
Step 2 :
Cable the lower CMA.
a.
Unlatch the elbow side of the CMA arm and swing it forward by pressing the blue button
that says “push” to unlatch it.
b.
Gather the SAS cables, one power cable, and one Ethernet cable to install in the left hand
side.
271
Содержание 1EX1231
Страница 1: ...User Guide Ultrastar Data102 Regulatory Model H4102 J Document D018 000226 000 Revision 04 May 2022...
Страница 16: ...User Guide Points of Contact xv...
Страница 110: ...User Guide 3 Support 3 7 CMA Replacement Figure 91 CMA Cable Routing c Open all of the baskets Figure 92 Open Baskets 94...