![Western Digital 1EX1231 Скачать руководство пользователя страница 157](http://html1.mh-extra.com/html/western-digital/1ex1231/1ex1231_user-manual_960951157.webp)
User Guide
3. Support
3.8 Rails Replacement
Figure 157:
Connected Cable Routing
e.
Connect the SAS cables and route them through the baskets one at a time. Follow the labels
to ensure they are connected to the proper ports.
f.
Important:
Make sure the power cable is not connected to a PDU
. If it is,
the system will power up when the cable is plugged into the PSU. This is not
intended at this stage of installation.
Connect the power cable to the lower PSU and route it through each basket.
g.
Close all of the baskets.
h.
If the Ultrastar Data102 is being installed in a rack and will subsequently be transported
inside that rack, it is important to use the included cable tie to wrap the CMA bundle to
ensure it does not get damaged during transport. If the Ultrastar Data102 is instead being
installed where it will operated, skip this step. Remember to remove the cable ties after the
enclosure has reached its final operational location.
i.
Reconnect the arm to the rail by the connector at the elbow.
Step 36 :
Cable the upper CMA.
a.
Unlatch the elbow side of the CMA arm and swing it forward by pressing the blue button
that says “push” to unlatch it.
141
Содержание 1EX1231
Страница 1: ...User Guide Ultrastar Data102 Regulatory Model H4102 J Document D018 000226 000 Revision 04 May 2022...
Страница 16: ...User Guide Points of Contact xv...
Страница 110: ...User Guide 3 Support 3 7 CMA Replacement Figure 91 CMA Cable Routing c Open all of the baskets Figure 92 Open Baskets 94...