6.10
6.20
10.10
10.20
Protective earth current
[mA]
-
-
-
-
Recommended conductor cross-section for wires laid uncovered in air up to 5 m
in length.
[mm
2
]
4G4
4G6
4G6
4G16
Residual-current device
Type
B
B
B
B
3~ 480V 50/60Hz
Rated power consumption
[kW]
10.9
19.3
19.3
33.4
Convection power
[kW]
10.5
18.9
18.9
33.0
Steam power
[kW]
9.0
18.0
18.0
27.0
Motor power
[kW]
0.35
0.35
0.35
0.35
Rated current
[A]
13.1
23.3
23.3
40.3
Fuse rating
[A]
16
25
25
50
Residual current
[mA]
-
-
-
-
Protective earth current
[mA]
-
-
-
-
Recommended conductor cross-section for wires laid uncovered in air up to 5 m
in length.
[mm
2
]
4G4
4G6
4G6
4G16
Residual-current device
Type
B
B
B
B
C4 ES (three-phase FC)
6.10
6.20
10.10
10.20
3~ 440V 50/60Hz
Rated power consumption
[kW]
9.2
16.3
16.3
28.2
Convection power
[kW]
8.8
15.9
15.9
27.8
Motor power
[kW]
0.35
0.35
0.35
0.35
Rated current
[A]
12.1
21.4
21.4
37.0
Fuse rating
[A]
16
25
25
50
Residual current
[mA]
-
-
-
-
Protective earth current
[mA]
-
-
-
-
Recommended conductor cross-section for wires laid uncovered in air up to 5 m
in length.
[mm
2
]
4G4
4G6
4G6
4G16
Residual-current device
Type
B
B
B
B
3~ 480V 50/60Hz
Rated power consumption
[kW]
10.9
19.3
19.3
33.4
Convection power
[kW]
10.5
18.9
18.9
33.0
Motor power
[kW]
0.35
0.35
0.35
0.35
Rated current
[A]
13.1
23.3
23.3
40.3
Fuse rating
[A]
16
25
25
50
Residual current
[mA]
-
-
-
-
Protective earth current
[mA]
-
-
-
-
Recommended conductor cross-section for wires laid uncovered in air up to 5 m
in length.
[mm
2
]
4G4
4G6
4G6
4G16
Residual-current device
Type
B
B
B
B
9.9 Gas specification, natural gas 2H (E), natural gas 2L (LL), propane 3P, liquefied gas 3B/P
C4 GB/GS
Gas type
Natural gas 2H
(E)
Natural gas 2L
(LL)
Propane 3P
Liquefied gas
3B/P
Standard test gas, code
G20
G25
G31
G30/G31
Operating materials
Natural gas, liquid gas
x
x
x
x
Gas supply values
9 Technical data
Installation manual
73