6.5.2 Connecting the fully automatic oven cleaning system
Connecting the fully automatic oven cleaning system to canisters
1.
Mix the supplied ConvoCare K concentrate with soft water in the empty
ConvoCare rinse aid canister.
Follow the instructions in the user manual on mixing the ConvoCare rinse aid
in the canister.
2.
Plug the green extractor tube (2) for the ConvoCare rinse aid onto the connec-
tor nipple of the rear tube fitting (F) and secure the tube in place with the wire
clip (3) (see label for rinse-aid connection on the left-hand side of the appli-
ance).
3.
Insert the suction nozzle on the green extractor tube (2) into the rinse aid can-
ister (1). There must be no kinks in the tube and the vent hole in the canister
must be open and unblocked.
6 Installation
Installation manual
58