6.10
6.20
10.10
10.20
Residual-current device
Type
A/B
A/B
A/B
A/B
3~ 230V 50/60Hz (3/PE)
Rated power consumption
[kW]
10.9
19.3
19.3
33.4
Convection power
[kW]
10.5
18.9
18.9
33.0
Motor power
[kW]
0.35
0.35
0.35
0.35
Rated current
[A]
27.4
48.5
48.5
84.0
Fuse rating
[A]
35
50
50
100
Residual current
[mA]
-
-
-
-
Protective earth current
[mA]
-
-
-
-
Recommended conductor cross-section for wires laid uncovered in air up to 5 m
in length.
[mm
2
]
4G6
4G16
4G16
4G35
Residual-current device
Type
A/B
A/B
A/B
A/B
9.4 Electrical supply, GB/GS
C4 GB (single-phase FC)
6.10
6.20
10.10
10.20
1N~ 230V 50/60Hz (1/N/PE)
Rated power consumption
[kW]
0.6
0.6
0.6
0.6
Convection power
[kW]
0.1
0.1
0.1
0.1
Steam power
[kW]
0.1
0.1
0.1
0.1
Motor power
[kW]
0.35
0.35
0.35
0.35
Rated current
[A]
2.7
2.7
2.7
2.7
Fuse rating
[A]
16
16
16
16
Residual current
[mA]
7.9
-
7.5
-
Protective earth current
[mA]
28.0
-
14.3
-
Recommended conductor cross-section for wires laid uncovered in
air up to 5 m in length.
[mm
2
]
3G2.5
3G2.5
3G2.5
3G2.5
Residual-current device
Type
A/B
A/B
A/B
A/B
C4 GS (single-phase FC)
6.10
6.20
10.10
10.20
1N~ 230V 50/60Hz (1/N/PE)
Rated power consumption
[kW]
0.6
0.6
0.6
0.6
Convection power
[kW]
0.1
0.1
0.1
0.1
Motor power
[kW]
0.35
0.35
0.35
0.35
Rated current
[A]
2.7
2.7
2.7
2.7
Fuse rating
[A]
16
16
16
16
Residual current
[mA]
7.0
7.0
6.9
-
Protective earth current
[mA]
28.0
33.0
-
-
Recommended conductor cross-section for wires laid uncovered in
air up to 5 m in length.
[mm
2
]
3G2.5
3G2.5
3G2.5
3G2.5
Residual-current device
Type
A/B
A/B
A/B
A/B
9.5 Electrical supply, Japan
C4 EB (single-phase FC)
6.10
6.20
10.10
10.20
3~ 200 V 50/60 Hz (3/PE)
9 Technical data
Installation manual
69