Torque Rotary Unit ST0055A / ST0075A / ST0140A
Mounting
8.5
Mounting additional components
WARNING
INCORRECT USE AND/OR FASTENING OF ADDITIONAL COMPONENTS
Failure to follow these instructions can result in death, serious injury, and
equipment damage.
■
Only mount components to the output flange that are approved by the
manufacturer.
■
Only use existing holes in the output flange for mounting additional components
to the output flange.
■
Do not drill holes into the output flange.
■
Do not attach further parts to the output flange (for example, by means of
welding) to mount additional components.
WARNING
IMPROPERLY FASTENED PARTS
Failure to follow these instructions can result in death, serious injury, and
equipment damage.
■
Verify that the supporting structure and/or the frame and/or the mounting surface
for fastening the product are sufficiently rated to withstand all static and dynamic
loads and forces during operation.
■
Verify that the fastening parts comply with the specifications indicated and that
they are sufficiently rated for all load conditions during operation.
Mounting the rotary plate
A rotary plate may only be mounted via the fit holes or threads.
If there is a centering collar at the stationary center part of the product, this centering collar must not be
used to fasten an additional indexing plate.
For this reason, the center hole of a rotary plate must be approx. 2 mm larger than the centering collar.
When determining the length of the screws, take into account the loads and forces acting in your
application as well as the characteristics of the supporting structure to which the product is mounted.
Mounting instructions_022019_3.0_en
27 / 47