Torque Rotary Unit ST0055A / ST0075A / ST0140A
Storage
7
Storage
7.1
Storing the product
NOTICE
INCORRECT STORAGE
Failure to follow these instructions can result in equipment damage.
■
Verify compliance with all conditions specified in these mounting instructions and
all applicable documents when storing the product.
The mechanical components of the product can be stored for a period of up to two years.
Conditions for the specified maximum storage duration:
■
Storage in original packaging
■
Compliance with all specified storage conditions
■
Storage in suitable closed, dry, dust-free room, protected against direct sunlight
■
No contact with corrosive media
■
Corrosion protection intact
The electrical components have a different maximum storage duration (see documentations of the
manufacturers).
If the maximum storage duration has been exceeded, you must contact the manufacturer prior
to commissioning the product. This also applies if the machine in which the product has been
incorporated has not been operated for a period of time exceeding the maximum storage durations
specified for the mechanical and electrical components.
If you plan to store the product for a period of time exceeding the maximum permissible storage
duration specified for the mechanical components, you must uninstall the electrical components prior
to storing the product. The electrical components must be stored according to the specifications of the
manufacturers (see documentations of the manufacturers).
If the product is to be stored for a period of more than three months, the product must first be
preserved. If the factory-applied anti-corrosion agent is no longer intact, you must request preservation
instructions from the manufacturer.
24 / 47